Elfgren, L., Enochsson, O., Täljsten, B. & Thun, H. (2013). Project: Sustainable Bridges. Paper presented at .
Åpne denne publikasjonen i ny fane eller vindu >>Project: Sustainable Bridges
2013 (svensk)Annet (Annet (populærvitenskap, debatt, mm))
Abstract [sv]

Ett EU-projekt med avsikt att förlänga livlängden för befinmtliga järnvägsbroar

HSV kategori
Forskningsprogram
Konstruktionsteknik
Identifikatorer
urn:nbn:se:ltu:diva-36105 (URN)6e15e0f1-4235-40d5-99ca-bf29dfd7b1a6 (Lokal ID)6e15e0f1-4235-40d5-99ca-bf29dfd7b1a6 (Arkivnummer)6e15e0f1-4235-40d5-99ca-bf29dfd7b1a6 (OAI)
Merknad

Publikationer: Defects in railway bridges and procedures for maintenance: UIC Code 778-4R; Loading to failure and 3D nonlinear FE modelling of a strengthened RC bridge.; Assessment of the Strengthening of an RC Railway Bridge with CFRP utilizing a Full-Scale Failure Test and Finite-Element Analysis; Tested versus code capacity of existing bridges: Three examples; Status: Avslutat; Period: 01/11/2003 → 31/10/2007

Tilgjengelig fra: 2016-09-30 Laget: 2016-09-30 Sist oppdatert: 2018-03-20bibliografisk kontrollert
Sabourova, N., Grip, N., Puurula, A., Enochsson, O., Tu, Y., Ohlsson, U., . . . Thun, H. (2012). The railway concrete arch bridge over Kalix river: dynamic properties and load carrying capacity (ed.). In: (Ed.), Dirch H Bager; Johan Silfwerbrand (Ed.), Concrete Structures for Sustainable Community: proceedings of the International FIB Symposium 2012, Stockholm, Sweden, 11 - 14 June 2012. Paper presented at FIB Symposium : Concrete Structures for Sustainable Community 11/06/2012 - 14/06/2012 (pp. 609-612). Stockholm: Swedish Concrete Association
Åpne denne publikasjonen i ny fane eller vindu >>The railway concrete arch bridge over Kalix river: dynamic properties and load carrying capacity
Vise andre…
2012 (engelsk)Inngår i: Concrete Structures for Sustainable Community: proceedings of the International FIB Symposium 2012, Stockholm, Sweden, 11 - 14 June 2012 / [ed] Dirch H Bager; Johan Silfwerbrand, Stockholm: Swedish Concrete Association , 2012, s. 609-612Konferansepaper, Publicerat paper (Fagfellevurdert)
sted, utgiver, år, opplag, sider
Stockholm: Swedish Concrete Association, 2012
HSV kategori
Forskningsprogram
Matematik; Konstruktionsteknik
Identifikatorer
urn:nbn:se:ltu:diva-27231 (URN)0995d66a-9097-44cb-838f-92a00c30f8bf (Lokal ID)978-91-980098-1-1 (ISBN)0995d66a-9097-44cb-838f-92a00c30f8bf (Arkivnummer)0995d66a-9097-44cb-838f-92a00c30f8bf (OAI)
Konferanse
FIB Symposium : Concrete Structures for Sustainable Community 11/06/2012 - 14/06/2012
Merknad
Godkänd; 2012; 20120328 (grip)Tilgjengelig fra: 2016-09-30 Laget: 2016-09-30 Sist oppdatert: 2018-03-27bibliografisk kontrollert
Thun, H., Ohlsson, U. & Elfgren, L. (2011). A deformation criterion for fatigue of concrete in tension (ed.). Paper presented at . Structural Concrete, 12(3), 187-197
Åpne denne publikasjonen i ny fane eller vindu >>A deformation criterion for fatigue of concrete in tension
2011 (engelsk)Inngår i: Structural Concrete, ISSN 1464-4177, E-ISSN 1751-7648, Vol. 12, nr 3, s. 187-197Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

A deformation criterion is proposed for the fatigue failure of concrete in tension. According to the criterion, a fatigue failure is imminent when the total deformation approaches the deformation at maximum stress in a corresponding static test. This criterion was originally proposed for bond slip by Balázs in 1991. It is tested on two series of new and old concrete cylinders loaded in cyclic tension. How the criterion may be used to predict the number of load cycles to failure for existing structures under cyclic tensile loading is also shown

HSV kategori
Forskningsprogram
Konstruktionsteknik
Identifikatorer
urn:nbn:se:ltu:diva-15516 (URN)10.1002/suco.201100013 (DOI)000295492100007 ()2-s2.0-80052408784 (Scopus ID)f0c45d5c-2d43-4cad-b2c8-48537bce705f (Lokal ID)f0c45d5c-2d43-4cad-b2c8-48537bce705f (Arkivnummer)f0c45d5c-2d43-4cad-b2c8-48537bce705f (OAI)
Merknad
Validerad; 2011; 20110927 (andbra)Tilgjengelig fra: 2016-09-29 Laget: 2016-09-29 Sist oppdatert: 2018-07-10bibliografisk kontrollert
Thun, H., Ohlsson, U. & Elfgren, L. (2009). Determination of concrete compressive strength with pullout tests (ed.). Paper presented at . Structural Concrete, 10(4), 173-180
Åpne denne publikasjonen i ny fane eller vindu >>Determination of concrete compressive strength with pullout tests
2009 (engelsk)Inngår i: Structural Concrete, ISSN 1464-4177, E-ISSN 1751-7648, Vol. 10, nr 4, s. 173-180Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

A pullout test using post-installed inserts has been examined as an alternative to drilled cores to determine the in-place concrete compressive strength. Tests have been carried out on eight railway bridges from 1965 to 1980 and on a one year old concrete slab. An empirical strength relationship is proposed between the compressive strength of a drilled core with the diameter and height of 100 mm and the pullout force from the pullout test. It is a power function and the relationship is valid for concrete compressive strengths up to 105 MPa; it gives higher concrete strengths than earlier proposed functions.

Emneord
Civil engineering and architecture - Building engineering, Samhällsbyggnadsteknik och arkitektur - Byggnadsteknik
HSV kategori
Forskningsprogram
Konstruktionsteknik
Identifikatorer
urn:nbn:se:ltu:diva-13039 (URN)10.1680/stco.2009.10.4.173 (DOI)000281641100003 ()2-s2.0-77949746261 (Scopus ID)c33640f0-fc66-11de-bae5-000ea68e967b (Lokal ID)c33640f0-fc66-11de-bae5-000ea68e967b (Arkivnummer)c33640f0-fc66-11de-bae5-000ea68e967b (OAI)
Merknad
Validerad; 2010; 20100108 (ulfols)Tilgjengelig fra: 2016-09-29 Laget: 2016-09-29 Sist oppdatert: 2018-07-10bibliografisk kontrollert
Elfgren, L., Enochsson, O., Puurula, A. & Thun, H. (2008). Field Test of a Concrete Bridge in Örnsköldsvik, Sweden: SB-7.3 Sustainable Bridges (ed.). Paper presented at . Luleå: SustainableBridges
Åpne denne publikasjonen i ny fane eller vindu >>Field Test of a Concrete Bridge in Örnsköldsvik, Sweden: SB-7.3 Sustainable Bridges
2008 (engelsk)Rapport (Fagfellevurdert)
Abstract [en]

Background - In the project Sustainable Bridges (www.sustainblebridges.net) important objectives are to increase the transport capacity and service life of existing bridges. In order to demonstrate new and refined methods developed in the program, field tests of existing bridges were carried out in Work Package 7. One of the bridges which have been tested is a 50 year old two-span concrete bridge located in Örnsköldsvik in northern Sweden.Due to time, legal and cost restraints, concrete bridges are seldom tested to failure. It was therefore deemed vital to carry out such a test here, as it is the only way to check if applied analytical and numerical models do catch the essential behaviour at failure of a structure.Objective - The Örnsköldsvik reinforced concrete bridge was loaded to failure to test new and refined methods developed in the project regarding procedures for inspection and condition assessment (WP 3), load carrying capacity in combined shear, torsion and bending (WP 4), monitoring (WP5), and strengthening (WP 6).To achieve a shear failure and to avoid an uninteresting bending failure, the bottom slab was strengthened before the final test. Near Surface Mounted Reinforcement (NSMR) was used consisting of Carbon Fibre Reinforced Polymers (CFRP).Results – The Bridge has two spans of 12 m. A loading beam made of steel was placed in the centre of one of the spans. The loading beam was then pulled down with cables injected to the bedrock beneath the bridge.The methods developed in the Sustainable Bridges program showed to be reliable. The inspection and condition assessment indicated that bridge was in good condition with almost no reinforcement corrosion. This was shown to be true. Material tests gave important contributions to steel and concrete properties. The load carrying capacity was underestimated with Swedish and European Codes, BBK04 and EN1992-2. combined with linear elastic finite element calculations. Better results were obtained with non-linear methods as the Modified Compression Field Theory (MCFT) and the non-linear finite element program Atena, recommended by the Guideline SB-LRA (2007) produced in the project. The monitoring methods used for concrete and steel strains, crack initiation, deflections and damage detection worked well. The strengthening method also worked very well. The bridge could carry a load of 11,7MN which was 20 to 50 % more than predictions based on BBK04 and EN 1992-2.The failure test showed that the bridge without strengthening managed to carry not only one train, as it was designed to do, but eight trains on top of each other with an axle load of 250 kN. With strengthening it could carry 11 trains. This shows that concrete railway bridges might have a considerable reserve of extra load-bearing capacity.

sted, utgiver, år, opplag, sider
Luleå: SustainableBridges, 2008. s. 406
Emneord
Civil engineering and architecture - Building engineering, Samhällsbyggnadsteknik och arkitektur - Byggnadsteknik
HSV kategori
Forskningsprogram
Konstruktionsteknik
Identifikatorer
urn:nbn:se:ltu:diva-23031 (URN)55681f69-58c2-4233-89d3-993af5e566c4 (Lokal ID)55681f69-58c2-4233-89d3-993af5e566c4 (Arkivnummer)55681f69-58c2-4233-89d3-993af5e566c4 (OAI)
Merknad

Godkänd; 2008; 20130725 (elfgren)

Tilgjengelig fra: 2016-09-29 Laget: 2016-09-29 Sist oppdatert: 2019-10-15bibliografisk kontrollert
Puurula, A., Enochsson, O., Thun, H., Nordin, H., Täljsten, B., Elfgren, L., . . . Olofsson, J. (2008). Full-scale test to failure of a strengthened reinforced concrete bridge: calibration of assessment models for load-bearing capacities of existing bridges (ed.). Paper presented at . Nordic Concrete Research (2), 131-142
Åpne denne publikasjonen i ny fane eller vindu >>Full-scale test to failure of a strengthened reinforced concrete bridge: calibration of assessment models for load-bearing capacities of existing bridges
Vise andre…
2008 (engelsk)Inngår i: Nordic Concrete Research, ISSN 0800-6377, nr 2, s. 131-142Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

A reinforced concrete railway trough bridge has been strengthened and loaded to failure. The aim was to test and calibrate methods developed in the European Research Project "Sustainable Bridges" regarding: (a) condition appraisal and inspection, (b) load carrying capacity analysis, (c) monitoring and (d) strengthening of existing bridges. The tested methods proved to be useful and to give accurate predictions. A failure in combined shear, bending and torsion was reached for an applied mid span load of 11,7 MN. This was well predicted by enhanced methods but 20 to 50 % higher than ultimate load evaluated according to predictions based on common codes and models.

HSV kategori
Forskningsprogram
Konstruktionsteknik
Identifikatorer
urn:nbn:se:ltu:diva-3768 (URN)199195a0-f1bc-11dd-ae0d-000ea68e967b (Lokal ID)199195a0-f1bc-11dd-ae0d-000ea68e967b (Arkivnummer)199195a0-f1bc-11dd-ae0d-000ea68e967b (OAI)
Merknad
Validerad; 2008; Bibliografisk uppgift: Publication no 38. ISBN 978-82-8208-011-8; 20090203 (elfgren)Tilgjengelig fra: 2016-09-29 Laget: 2016-09-29 Sist oppdatert: 2018-03-20bibliografisk kontrollert
Thun, H., Utsi, S. & Elfgren, L. (2008). Load carrying capacity of cracked concrete railway sleepers (ed.). Paper presented at . Structural Concrete, 9(3), 153-161
Åpne denne publikasjonen i ny fane eller vindu >>Load carrying capacity of cracked concrete railway sleepers
2008 (engelsk)Inngår i: Structural Concrete, ISSN 1464-4177, E-ISSN 1751-7648, Vol. 9, nr 3, s. 153-161Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

The load carrying capacity of damaged prestressed concrete railway sleepers has been investigated in order get information about how the cracking influences the remaining load carrying capacity compared to an un-cracked sleeper. The following tests have been performed: bending capacity of the midsection, the rail section, horizontal load capacity of the fastener, control of the concrete properties and fatigue capacity in bending of the rail section. A visual inspection and classification of the damages are also presented. The test results have been compared with calculations according to the Swedish railway code for sleepers and show that railway sleepers are quite robust. Small cracks do not seem to influence the load carrying capacity and it is first when the cracking is very severe that the load carrying capacity is reduced significantly.

Abstract [en]

The load carrying capacity of damaged prestressed concrete railway sleepers has been investigated in order to obtain information about how the cracking influences the remaining load carrying capacity compared with an uncracked sleeper. The following tests have been performed: bending capacity of the midsection, the rail section, horizontal load capacity of the fastener, control of the concrete properties and fatigue capacity in bending of the rail section. A visual inspection and classfication of the damages are also presented. The test results have been compared with calculations according to the Swedish railway code for sleepers and show that railway sleepers are quite robust. Small cracks do not seem to influence the load carrying capacity and it is first when the cracking is very severe that the load carrying capacity is reduced significantly. Udgivelsesdato: september

HSV kategori
Forskningsprogram
Konstruktionsteknik
Identifikatorer
urn:nbn:se:ltu:diva-2871 (URN)10.1680/stco.2008.9.3.153 (DOI)0979d1b0-96ad-11dd-aadc-000ea68e967b (Lokal ID)0979d1b0-96ad-11dd-aadc-000ea68e967b (Arkivnummer)0979d1b0-96ad-11dd-aadc-000ea68e967b (OAI)
Merknad
Validerad; 2008; 20081010 (thun)Tilgjengelig fra: 2016-09-29 Laget: 2016-09-29 Sist oppdatert: 2017-11-24bibliografisk kontrollert
Puurula, A., Enochsson, O., Thun, H., Täljsten, B., Elfgren, L., Olofsson, J. & Paulsson, B. (2008). Test of a concrete bridge in Sweden: I. Assessment methods (ed.). In: (Ed.), Hyun-Moo Koh; Dan M Frangopol (Ed.), Bridge Maintenance, Safety, Management, Health Monitoring and Informatics: Proceedings of the fourth International Conference on Bridge Maintenance, Safety and Management, Seoul, Korea, 13-17 July 2008. Paper presented at International Conference on Bridge Maintenance, Safety and Management : 13/07/2008 - 17/07/2008 (pp. 3385-3592). Boca Raton, Fla: Taylor and Francis Group
Åpne denne publikasjonen i ny fane eller vindu >>Test of a concrete bridge in Sweden: I. Assessment methods
Vise andre…
2008 (engelsk)Inngår i: Bridge Maintenance, Safety, Management, Health Monitoring and Informatics: Proceedings of the fourth International Conference on Bridge Maintenance, Safety and Management, Seoul, Korea, 13-17 July 2008 / [ed] Hyun-Moo Koh; Dan M Frangopol, Boca Raton, Fla: Taylor and Francis Group , 2008, s. 3385-3592Konferansepaper, Publicerat paper (Fagfellevurdert)
sted, utgiver, år, opplag, sider
Boca Raton, Fla: Taylor and Francis Group, 2008
HSV kategori
Forskningsprogram
Konstruktionsteknik
Identifikatorer
urn:nbn:se:ltu:diva-40284 (URN)f5b95480-b032-11dd-b677-000ea68e967b (Lokal ID)978-0-415-46844-2 (ISBN)f5b95480-b032-11dd-b677-000ea68e967b (Arkivnummer)f5b95480-b032-11dd-b677-000ea68e967b (OAI)
Konferanse
International Conference on Bridge Maintenance, Safety and Management : 13/07/2008 - 17/07/2008
Merknad
Godkänd; 2008; 20081111 (elfgren)Tilgjengelig fra: 2016-10-03 Laget: 2016-10-03 Sist oppdatert: 2018-03-20bibliografisk kontrollert
Enochsson, O., Puurula, A., Thun, H., Elfgren, L., Täljsten, B., Olofsson, J. & Paulsson, B. (2008). Test of a concrete bridge in Sweden: III. Ultimate capacity (ed.). In: (Ed.), Hyun-Moo Koh; Dan G Frangopol (Ed.), Bridge Maintenance, Safety Management, Health Monitoring and Informatics: Proceedings of the Fourth International Conference on Bridge Maintenance, Safety and Management, July 13-17 2008, Seoul, Korea - IABMAS '08. Paper presented at International Conference on Bridge Maintenance, Safety and Management : 13/07/2008 - 17/07/2008 (pp. 3601-3608). Boca Raton, Fla: Taylor and Francis Group
Åpne denne publikasjonen i ny fane eller vindu >>Test of a concrete bridge in Sweden: III. Ultimate capacity
Vise andre…
2008 (engelsk)Inngår i: Bridge Maintenance, Safety Management, Health Monitoring and Informatics: Proceedings of the Fourth International Conference on Bridge Maintenance, Safety and Management, July 13-17 2008, Seoul, Korea - IABMAS '08 / [ed] Hyun-Moo Koh; Dan G Frangopol, Boca Raton, Fla: Taylor and Francis Group , 2008, s. 3601-3608Konferansepaper, Publicerat paper (Fagfellevurdert)
sted, utgiver, år, opplag, sider
Boca Raton, Fla: Taylor and Francis Group, 2008
HSV kategori
Forskningsprogram
Konstruktionsteknik
Identifikatorer
urn:nbn:se:ltu:diva-30837 (URN)4d148a90-b035-11dd-b677-000ea68e967b (Lokal ID)978-0-415-46844-2 (ISBN)4d148a90-b035-11dd-b677-000ea68e967b (Arkivnummer)4d148a90-b035-11dd-b677-000ea68e967b (OAI)
Konferanse
International Conference on Bridge Maintenance, Safety and Management : 13/07/2008 - 17/07/2008
Merknad
Godkänd; 2008; 20081111 (elfgren)Tilgjengelig fra: 2016-09-30 Laget: 2016-09-30 Sist oppdatert: 2018-03-20bibliografisk kontrollert
Thun, H., Ohlsson, U. & Elfgren, L. (2007). Tensile fatigue capacity of concrete (ed.). Paper presented at . Nordic Concrete Research, 36(1-2), 48-64
Åpne denne publikasjonen i ny fane eller vindu >>Tensile fatigue capacity of concrete
2007 (engelsk)Inngår i: Nordic Concrete Research, ISSN 0800-6377, Vol. 36, nr 1-2, s. 48-64Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Results and analyses are presented from cyclic uniaxial tensile tests on plain cylindrical concrete cores. The influence of the load amplitude and the mean load level were studied with so called factorial design. It was found that both factors were important but that neither of them could be established to be more important than the other. Further, the deformation rate was studied. It appears that a certain fatigue limit exists below which a clearly greater number of load cycles is required for failure. From this research the exact limit cannot be predicted, but for tests with a mean load level of 40% of fpeak and an amplitude of 40% of fpeak, a very low deformation rate has been obtained. Finally, the test results have been compared with other Wöhler curves proposed for cyclic load in tension.

HSV kategori
Forskningsprogram
Konstruktionsteknik
Identifikatorer
urn:nbn:se:ltu:diva-12309 (URN)b6c69090-d562-11dc-958e-000ea68e967b (Lokal ID)b6c69090-d562-11dc-958e-000ea68e967b (Arkivnummer)b6c69090-d562-11dc-958e-000ea68e967b (OAI)
Merknad
Validerad; 2007; 20080207 (thun)Tilgjengelig fra: 2016-09-29 Laget: 2016-09-29 Sist oppdatert: 2018-03-27bibliografisk kontrollert