Öppna denna publikation i ny flik eller fönster >>2014 (Engelska)Ingår i: 1st Global Conference on Biomedical Engineering & 9th Asian-Pacific Conference on Medical and Biological Engineering: October 9-12, 2014, Tainan, Taiwan / [ed] Fong-Chin Su; Shyh-Hau Wang; Ming-Long Yeh, New York: Encyclopedia of Global Archaeology/Springer Verlag, 2014, s. 267-270Konferensbidrag, Publicerat paper (Refereegranskat)
Abstract [en]
Prostate cancer (PCa) is the most common cancer form for men in Europe. A sensor system combining Raman spectroscopy and stiffness sensing with a resonance sensor has recently been developed by us for prostate cancer detection. In this study the sensor system has been used for measurements on two slices of fresh human prostate tissue. The stiffness sensor could detect locations slices with significantly different stiffness contrasts (p < 0.05). Raman spectroscopic measurements could be performed with the dual-modality probe for tissue classification. The findings are important for the continued development of a combination probe for prostate cancer detection.
Ort, förlag, år, upplaga, sidor
New York: Encyclopedia of Global Archaeology/Springer Verlag, 2014
Serie
International Federation for Medical and Biological Engineering Proceedings, ISSN 1680-0737 ; 47
Nyckelord
Fiber optical Raman spectroscopy, tactile re-sonance sensor technology, histopathology, prostate cancer detection, radical
Nationell ämneskategori
Medicinsk laboratorieteknik
Forskningsämne
Experimentell mekanik; Centrumbildning - Centrum för medicinsk teknik och fysik (CMTF)
Identifikatorer
urn:nbn:se:ltu:diva-40175 (URN)10.1007/978-3-319-12262-5_74 (DOI)000349915800074 ()2-s2.0-84914821295 (Scopus ID)f321d7ae-a17f-459a-9a14-a32f492b51a2 (Lokalt ID)978-3-319-12262-5 (ISBN)978-3-319-12262-5 (ISBN)f321d7ae-a17f-459a-9a14-a32f492b51a2 (Arkivnummer)f321d7ae-a17f-459a-9a14-a32f492b51a2 (OAI)
Konferens
Global Conference on Biomedical Engineering : 09/10/2014 - 12/10/2014
Anmärkning
Godkänd; 2014; 20141029 (ramser);
For correction, see: Lindahl, O.A., Nyberg, M., Jalkanen, V., Ramser, K. (2015). Erratum: Prostate Cancer Detection Using a Combination of Raman Spectroscopy and Stiffness Sensing. In: Su, FC., Wang, SH., Yeh, ML. (eds) 1st Global Conference on Biomedical Engineering & 9th Asian-Pacific Conference on Medical and Biological Engineering. IFMBE Proceedings, vol 47. Springer, Cham. https://doi.org/10.1007/978-3-319-12262-5_75
2016-10-032016-10-032025-02-09Bibliografiskt granskad