RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Reliability and Validity of Running Step Rate Derived From a Novel Wearable Smart Patch
Department of Health Sciences, Mid Sweden University, 83125 Östersund, Sweden; Faculty of Sport, University of Ljubljana, 1000 Ljubljana, Slovenia.
Faculty of Sport, University of Ljubljana, Ljubljana, Slovenia.
Department of Materials Science and Engineering, Division of Microsystems Technology, Ångström Laboratory, Uppsala University, Uppsala, Sweden.
STMicroelectronics, Milan, Italy.
Vise andre og tillknytning
2024 (engelsk)Inngår i: IEEE Sensors Journal, ISSN 1530-437X, E-ISSN 1558-1748, Vol. 24, nr 9, s. 14343-14351Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

A novel, wearable, stretchable Smart Patch can monitor various aspects of physical activity, including the dynamics of running. However, like any new device developed for such applications, it must first be tested for validity and reliability. Here, we compare the step rate while running on a treadmill measured by this smart patch with the corresponding values obtained with the ”gold standard” OptoGait, as well as with other devices commonly used to assess running dynamics, i.e., the MEMS accelerometer and commercially available and widely used Garmin Running Dynamic Pod. The 14 healthy, physically active volunteers completed two identical sessions with a 5-minute rest between. Each session involved two one-minute runs at 11 km/h and 14 km/h separated by a one-min rest. The major finding was that the Smart Patch demonstrated fair to good test-retest reliability. The best test-retest reliability for the Running Pod was observed in connection with running at 11 km/h and both velocities combined (good and excellent, respectively) and for the OptoGait when running at 14 km/h (good). The best concurrent validity was achieved with the Smart Patch, as reflected in the highest Pearson correlation coefficient for this device when running at 11 or 14 km/h, as well as for both velocities combined. In conclusion, this study demonstrates that the novel wearable Smart Patch shows promising reliability and excellent concurrent validity in measuring step rate during treadmill running, making it a viable tool for both research and practical applications in sports and exercise science.

sted, utgiver, år, opplag, sider
IEEE, 2024. Vol. 24, nr 9, s. 14343-14351
Emneord [en]
Garmin Running Pod, MEMS accelerometers, OptoGait, reliability, running, Smart Patch, treadmill, validity
HSV kategori
Forskningsprogram
Fysioterapi; Centrumbildning - Centrum för idrotts- och prestationsteknologi (SPORTC)
Identifikatorer
URN: urn:nbn:se:ltu:diva-104866DOI: 10.1109/JSEN.2024.3370304Scopus ID: 2-s2.0-85187352291OAI: oai:DiVA.org:ltu-104866DiVA, id: diva2:1846772
Forskningsfinansiär
EU, Horizon 2020, 824984
Merknad

Validerad;2024;Nivå 2;2024-05-21 (joosat);

Full text license: CC BY-NC-ND 4.0;

Funder: Slovenian Research and Innovation Agency under Research Core Funding (Grant P5-0147);

Tilgjengelig fra: 2024-03-25 Laget: 2024-03-25 Sist oppdatert: 2024-05-21bibliografisk kontrollert

Open Access i DiVA

fulltext(15350 kB)6 nedlastinger
Filinformasjon
Fil FULLTEXT02.pdfFilstørrelse 15350 kBChecksum SHA-512
b22dbb2d98cb08446535e8a6f0bd93e74fde33b1a581bbb6086a4cd4b470ed9c7649952a951dc7e8ec415dff22e8a37a694154843de79cf84f5aeca9cfcc0f25
Type fulltextMimetype application/pdf

Andre lenker

Forlagets fulltekstScopus

Person

Holmberg, Hans-Christer

Søk i DiVA

Av forfatter/redaktør
Holmberg, Hans-Christer
Av organisasjonen
I samme tidsskrift
IEEE Sensors Journal

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 45 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 272 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf