Monitoring the setting of injectable calcium-based bone cements using pulse-echo ultrasound
Luleå tekniska universitet, Institutionen för system- och rymdteknik, Signaler och system.ORCID-id: 0000-0002-6216-6132
Polytechnical University of Catalonia, Barcelona.
Polytechnical University of Catalonia, Barcelona.
Polytechnical University of Catalonia, Barcelona.
2002 (engelsk)Inngår i: Proceedings: 2002 IEEE Ultrasonics Symposium : October 8 - 11, 2002, Forum Hotel, Munich, Germany ; an international symposium / [ed] Donald E. Yuhas, Piscataway, NJ: IEEE Communications Society, 2002, s. 1293-1296Konferansepaper, Publicerat paper (Fagfellevurdert)
Abstract [en]

The existing standards for determining the setting time of injectable bone substitutes suffers from poor reproducibility and subjectivity. We previously presented an ultrasonic pulse-echo technique that can follow the entire setting reaction on-line, without any mechanical manipulation of the sample. For calcium sulfate hemihydrate (CSH), the new method shows good agreement with the standards, but with much better reproducibility. One problem with the new technique was its sensitivity to temperature fluctuations. In this paper we present a temperature compensation scheme that automatically corrects the measurements for losses caused by temperature changes. The modified method is verified with experiments on /spl alpha/-tricalcium phosphate (/spl alpha/-TCP). Because /spl alpha/-TCP has longer setting time than CSH, the initial method, which is sensitive to temperature, did not work.

sted, utgiver, år, opplag, sider
Piscataway, NJ: IEEE Communications Society, 2002. s. 1293-1296
HSV kategori
Forskningsprogram
Signalbehandling
Identifikatorer
URN: urn:nbn:se:ltu:diva-39266DOI: 10.1109/ULTSYM.2002.1192531Lokal ID: dee7b850-6390-11db-8cbe-000ea68e967bISBN: 0-7803-7582-3 (tryckt)OAI: oai:DiVA.org:ltu-39266DiVA, id: diva2:1012776
Konferanse
IEEE Ultrasonics Symposium : 08/10/2002 - 11/10/2002
Merknad
Godkänd; 2002; 20061024 (ysko)Tilgjengelig fra: 2016-10-03 Laget: 2016-10-03 Sist oppdatert: 2017-11-25bibliografisk kontrollert

Open Access i DiVA

fulltekst(159 kB)76 nedlastinger
Filinformasjon
Fil FULLTEXT01.pdfFilstørrelse 159 kBChecksum SHA-512
8887205ae26deab4b01f7431267e1ff121f09d8530962130e90d2dbef81183da1d85f76791a4adda08f78b9753b859a772261be166cdb2818ca9b5875c5e8274
Type fulltextMimetype application/pdf

Andre lenker

Forlagets fulltekst

Personposter BETA

Carlson, Johan

Søk i DiVA

Av forfatter/redaktør
Carlson, Johan
Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 76 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

doi
isbn
urn-nbn

Altmetric

doi
isbn
urn-nbn
Totalt: 41 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf