Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Sensitivity improvements of a resonance-based tactile sensor
Department of Electrical and Electronics Engineering, College of Engineering , Nihon University .
Luleå tekniska universitet, Institutionen för teknikvetenskap och matematik, Strömningslära och experimentell mekanik.
Rekke forfattare: 22017 (engelsk)Inngår i: Journal of Medical Engineering & Technology, ISSN 0309-1902, E-ISSN 1464-522X, Vol. 41, nr 2, s. 131-140Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Resonance-based contact-impedance measurement refers to the application of resonance sensors based on the measurement of the changes in the resonance curve of an ultrasonic resonator in contact with a surface. The advantage of the resonance sensor is that it is very sensitive to small changes in the contact impedance. A sensitive micro tactile sensor (MTS) was developed, which measured the elasticity of soft living tissues at the single-cell level. In the present paper, we studied the method of improving the touch and stiffness sensitivity of the MTS. First, the dependence of touch sensitivity in relation to the resonator length was studied by calculating the sensitivity coefficient at each length ranging from 9 to 40 mm. The highest touch sensitivity was obtained with a 30-mm-long glass needle driven at a resonance frequency of 100 kHz. Next, the numerical calculation of contact impedance showed that the highest stiffness sensitivity was achieved when the driving frequency was 100 kHz and the contact-tip diameter of the MTS was 10 μm. The theoretical model was then confirmed experimentally using a phase-locked-loop-based digital feedback oscillation circuit. It was found that the developed MTS, whose resonant frequency was 97.030 kHz, performed with the highest sensitivity of 53.2 × 106 Hz/N at the driving frequency of 97.986 kHz, i.e. the highest sensitivity was achieved at 956 Hz above the resonant frequency.

sted, utgiver, år, opplag, sider
Taylor & Francis, 2017. Vol. 41, nr 2, s. 131-140
HSV kategori
Forskningsprogram
Experimentell mekanik
Identifikatorer
URN: urn:nbn:se:ltu:diva-59615DOI: 10.1080/03091902.2016.1239278PubMedID: 27701917Scopus ID: 2-s2.0-84990201247OAI: oai:DiVA.org:ltu-59615DiVA, id: diva2:1033821
Merknad

Validerad; 2017; Nivå 2; 2016-12-20 (andbra)

Tilgjengelig fra: 2016-10-10 Laget: 2016-10-10 Sist oppdatert: 2018-11-15bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstPubMedScopus

Personposter BETA

Lindahl, Olof

Søk i DiVA

Av forfatter/redaktør
Lindahl, Olof
Av organisasjonen
I samme tidsskrift
Journal of Medical Engineering & Technology

Søk utenfor DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric

doi
pubmed
urn-nbn
Totalt: 222 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf