Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Full-field 3D deformation measurement: Comparison between speckle phase and displacement evaluation
Luleå tekniska universitet, Institutionen för teknikvetenskap och matematik, Strömningslära och experimentell mekanik.
Institute of Applied Optics, University of Stuttgart.
Institute of Applied Optics, University of Stuttgart.
Luleå tekniska universitet, Institutionen för teknikvetenskap och matematik, Strömningslära och experimentell mekanik.ORCID-id: 0000-0003-4879-8261
Rekke forfattare: 42016 (engelsk)Inngår i: Applied Optics, ISSN 1559-128X, E-ISSN 2155-3165, Vol. 55, nr 27, s. 7735-7743Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

The objective of this paper is to describe a full-field deformation measurement method based on 3D speckle displacements. The deformation is evaluated from the slope of the speckle displacement function that connects the different reconstruction planes. For our experiment, a symmetrical arrangement with four illuminations parallel to the planes (x,z) and (y,z) was used. Four sets of speckle patterns were sequentially recorded by illuminating an object from the four directions, respectively. A single camera is used to record the holograms before and after deformations. Digital speckle photography is then used to calculate relative speckle displacements in each direction between two numerically propagated planes. The 3D speckle displacements vector is calculated as a combination of the speckle displacements from the holograms recorded in each illumination direction. Using the speckle displacements, problems associated with rigid body movements and phase wrapping are avoided. In our experiment, the procedure is shown to give the theoretical accuracy of 0.17 pixels yielding the accuracy of 2 × 10-3 in the measurement of deformation gradients

sted, utgiver, år, opplag, sider
2016. Vol. 55, nr 27, s. 7735-7743
HSV kategori
Forskningsprogram
Strömningslära
Identifikatorer
URN: urn:nbn:se:ltu:diva-59937DOI: 10.1364/AO.55.007735ISI: 000383996900038Scopus ID: 2-s2.0-8498881167OAI: oai:DiVA.org:ltu-59937DiVA, id: diva2:1039901
Merknad

Validerad; 2016; Nivå 2; 2016-10-25 (andbra)

Tilgjengelig fra: 2016-10-25 Laget: 2016-10-25 Sist oppdatert: 2018-07-10bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstScopus

Personposter BETA

Khodadad, DavoodSjödahl, Mikael

Søk i DiVA

Av forfatter/redaktør
Khodadad, DavoodSjödahl, Mikael
Av organisasjonen
I samme tidsskrift
Applied Optics

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 283 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf