Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Synthesis of Sheet Like Morphology of NiO for Sensitive and Selective Determination of Urea
National Centre of Excellence in Analytical Chemistry, University of Sindh, Jamshoro, 76080, Pakistan.ORCID-id: 0000-0001-6777-5642
National Centre of Excellence in Analytical Chemistry, University of Sindh, Jamshoro, 76080, Pakistan.
National Centre of Excellence in Analytical Chemistry, University of Sindh, Jamshoro, 76080, Pakistan.
National Centre of Excellence in Analytical Chemistry, University of Sindh, Jamshoro, 76080, Pakistan.
Vise andre og tillknytning
2017 (engelsk)Inngår i: Sensor Letters, ISSN 1546-198X, E-ISSN 1546-1971, Vol. 15, nr 10, s. 803-810Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

An efficient and simple method has been demonstrated for the synthesis of nickel oxide nanostructures using urea as a capping agent. The nanosheet-like morphology was confirmed by scanning electron microscopy, crystalline nature was studied by using the X-ray diffraction (XRD) and surface area of nanomaterial was investigated by automated sorption analyzer. Then synthesized NiO nanostructures were used to fabricate the surface of glassy carbon electrode (GCE). The electrocatalytic parameters of modified NiO/GCE electrode were investigated by using various techniques such as electrochemical impedance spectroscopy (EIS), square wave voltammetry (SWV), differential pulse voltammetry (DPV), normal pulse voltammetry (NPV) and cyclic voltammetry (CV) and chronoamperometry. Various working experimental conditions were optimized in order to attain the highest sensitivity for the determination of urea and the highest peak current 1032 μA of response were obtained at 100 μM concentration of urea. A linear calibration plot was obtained for peak current versus concentration of urea in the range of 10 μM urea to 80 μM urea with a good detection limit of 2 μM. The proposed working strategy was successfully employed for the estimation of urea in human urine samples and the obtained results are found satisfactory. The newly functional urea sensor can be exploited at large scale as an alternative analytical device beside to the other reported urea sensors

sted, utgiver, år, opplag, sider
American Scientific Publishers, 2017. Vol. 15, nr 10, s. 803-810
HSV kategori
Forskningsprogram
Experimentell fysik
Identifikatorer
URN: urn:nbn:se:ltu:diva-67597DOI: 10.1166/sl.2017.3875OAI: oai:DiVA.org:ltu-67597DiVA, id: diva2:1181883
Merknad

Validerad;2018;Nivå 1;2018-02-12 (andbra)

Tilgjengelig fra: 2018-02-10 Laget: 2018-02-10 Sist oppdatert: 2018-04-26bibliografisk kontrollert

Open Access i DiVA

fulltext(566 kB)236 nedlastinger
Filinformasjon
Fil FULLTEXT01.pdfFilstørrelse 566 kBChecksum SHA-512
eed1d10a4c01884259bf24a251d64847e697db37c6e8b192124e52cc47ada11baa108d937d1c63f202da2277fee09af3687329358a9c76ae6da346c83c5a5fb3
Type fulltextMimetype application/pdf

Andre lenker

Forlagets fulltekst

Søk i DiVA

Av forfatter/redaktør
Kumar, RajTahira, AneelaIbupoto, Zafar Hussain
Av organisasjonen
I samme tidsskrift
Sensor Letters

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 236 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 88 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf