Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Carry distance of top-of-rail friction modifiers
Luleå tekniska universitet, Institutionen för samhällsbyggnad och naturresurser, Drift, underhåll och akustik.ORCID-id: 0000-0002-9723-2881
Luleå tekniska universitet, Institutionen för samhällsbyggnad och naturresurser, Drift, underhåll och akustik.
Luleå tekniska universitet, Institutionen för samhällsbyggnad och naturresurser, Drift, underhåll och akustik.ORCID-id: 0000-0002-0188-4624
2018 (engelsk)Inngår i: Proceedings of the Institution of mechanical engineers. Part F, journal of rail and rapid transit, ISSN 0954-4097, E-ISSN 2041-3017, Vol. 232, nr 10, s. 2418-2430Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Rail issues such as corrugation, rolling contact fatigue, noise and wear have been increasing with the increase in railway traffic. The application of top-of-rail friction modifiers (TOR-FMs) is claimed by their manufacturers in the railway industry to be a well-established technique for resolving the above-mentioned issues. There are various methods for applying friction modifiers at the wheel–rail interface, among which stationary wayside systems are recommended by TOR-FM manufacturers when a distance of a few kilometres is to be covered. TOR-FM manufacturers also claim that by using wayside equipment, the TOR-FM can be spread over a minimum distance of 3 km, over which it maintains a coefficient of friction of µ = 0.35 ± 0.05. To determine the carry distance of TOR-FMs, some researchers use tribometers to measure the coefficients of friction. However, moisture and deposits from the environment and trains can alter the top-of-rail friction and give a misleading indication of the presence of a friction modifier. Therefore, the coefficient of friction itself is not a clear indicator of the presence of TOR-FMs. In the present study, cotton swabs dipped in a mixture of alcohol and ester were used to collect surface deposits (a third body) from both the wheel and rail at various distances from the point of application. Subsequently, the third body collected on the cotton swab was analysed using an energy dispersive X-ray analysis. The results have shown that the maximum carry distance of TOR-FMs on the top of the rail is limited to 70 m when using a TOR-FM from one manufacturer and to 450 m when using a TOR-FM from another manufacturer. The carry distance on the contact band of the wheel is limited to 100 m and 340 m. The friction modifier on the edges of the contact band was detected over a distance of up to 3 km; however, this will not minimise the damage or friction at the wheel–rail interface.

sted, utgiver, år, opplag, sider
Sage Publications, 2018. Vol. 232, nr 10, s. 2418-2430
Emneord [en]
Friction modifier, carry distance, top-of-rail, wayside equipment, top-of-rail friction modifier
HSV kategori
Forskningsprogram
Drift och underhållsteknik
Identifikatorer
URN: urn:nbn:se:ltu:diva-68850DOI: 10.1177/0954409718772981ISI: 000450295400007Scopus ID: 2-s2.0-85056728671OAI: oai:DiVA.org:ltu-68850DiVA, id: diva2:1209286
Merknad

Validerad;2018;Nivå 2;2018-11-30 (svasva)

Tilgjengelig fra: 2018-05-22 Laget: 2018-05-22 Sist oppdatert: 2019-02-07bibliografisk kontrollert
Inngår i avhandling
1. Effects of top-of-rail friction modifiers on the friction, wear and cracks of railway rails
Åpne denne publikasjonen i ny fane eller vindu >>Effects of top-of-rail friction modifiers on the friction, wear and cracks of railway rails
2019 (engelsk)Doktoravhandling, med artikler (Annet vitenskapelig)
Alternativ tittel[sv]
Effekter av top-of-rail friktionsmodifierare på friktion, slitage och sprickor på järnvägsräls
Abstract [en]

The railway is an economical and environmentally friendly mode of transport for long distances and heavy loads. The demands on the operators are increasing with increased competition in the market, and therefore they are currently demanding more track capacity. In the short term, the existing network is expected to deliver the increased capacity. In order to achieve increased capacity without introducing double track, either the axle load or the number of trains (i.e. the annual gross tonnage) needs to be increased, which will decrease the life of the rail and thus increase the maintenance cost. To increase the lifetime of the rails without compromising with regard to the axle load and speed, one must increase the strength of the rails, decrease the traction forces between the rails and wheels, or introduce a third body with anti-wear and anti-crack properties that can reduce the wear and rolling contact fatigue (RCF) without reducing the traction forces below the safety limit.

The traction forces depend on several variables, for example third bodies in the wheel-rail interface, the train dynamics, the wheel and rail profiles, etc. Third bodies in the wheel-rail interface are one of the important influencing factors. The additive third bodies with anti-wear properties and friction reduction capabilities reduces both the wear and the RCF. However, a friction coefficient in the wheel tread and the top of the rail below 0.3 can cause slippage and a long braking distance. To reduce the degree of utilised friction to a value close to 0.35 from dry conditions with a value of 0.55, and thereby reduce the wear, a product known as top-of-rail friction modifier (TOR-FM) was developed in North America and presented in 2003 at the heavy haul conference. The TOR-FM manufacturers claim that their products provide a fixed range of friction coefficients (μ) and Kalker’s coefficients in the wheel-rail interface. Kalker’s coefficient considers the tendency of creepage between the rail and wheel as a function of the traction forces at lower creepage levels. Field and laboratory tests in the USA, Canada and China have determined the benefits of using friction control products, which include the reduction of RCF, wear, corrugation, bogie hunting, noise, and fuel consumption without any side effects. In contrast, researchers at Luleå University of Technology (LTU) have found that such products in certain conditions give unacceptably low friction that can cause long braking distances and slippage. Initial measurements performed using a wayside TOR-FM system on the Iron Ore Line (IOL – “Malmbanan” in Swedish) could not find any benefits of implementing such systems.

Trafikverket is considering the implementation of the TOR-FM technology on the IOL. Directly implementing such technology can be inappropriate and expensive, because the reliability of a TOR-FM system has never been assessed for the conditions of the IOL. The IOL is the northernmost railway line in Sweden and is experiencing the problem of RCF, especially on its curves. This railway line is a single track and is mainly utilised by the ore freight trains operated by the Swedish mining company LKAB. The freight trains run by LKAB have an axle load of 30 tonnes, which is the heaviest in Europe. At present LKAB is planning to increase the axle load of their heavy haul trains to 32.5 tonnes, which will increase the RCF and wear issues.

The present research investigated the effects of TOR-FMs using computer-based simulations, laboratory tests and field tests. The results from all the tests and simulations were used to calculate the life cycle cost of wayside and on-board systems. The simulation results have shown that by reducing the friction, the RCF can be reduced. This reduction in the RCF is greater on narrow curves than on larger curves as the traction forces decrease with an increase in the curve radius. Curves with a radius larger than m are not prone to RCF. The damage index method used in the simulation has also shown that on circular curves with a radius smaller than 300 m, the so-called “magic wear” rate can be achieved. Magic wear means that the wear rate due to normal operation is equal to the crack generation rate. The field results obtained using a handheld tribometer have shown that by using a TOR-FM, both the wear and the friction coefficients can be reduced. The content of the TOR-FM can have a significant effect on the carry distance and, generally, non-drying FMs have a longer carry distance. Excessive use of TOR-FM may cause unacceptably low friction and a high operational cost, and only result in an insignificant increase in the carry distance. In addition, it was also concluded that in the case of the wayside system during extreme winters, the equipment could have maintenance issues and thus a high operational cost. The on-board system is an economical alternative to the wayside system, as it has lower operation and maintenance costs. The results have also shown that snow and ice formation in the winter act as a lubricant. However, further investigations are needed to provide knowledge of the efficiency of such natural lubricants and their retention on the rail. The present research has taken the IOL as a case study, but the results will be applicable all over the world.

 

sted, utgiver, år, opplag, sider
Luleå: Luleå University of Technology, 2019
Serie
Doctoral thesis / Luleå University of Technology 1 jan 1997 → …, ISSN 1402-1544
HSV kategori
Forskningsprogram
Drift och underhållsteknik
Identifikatorer
urn:nbn:se:ltu:diva-71613 (URN)978-91-7790-272-0 (ISBN)978-91-7790-273-7 (ISBN)
Disputas
2019-02-14, F1031, Luleå Tekniska Universitet, Luleå, 09:30 (engelsk)
Opponent
Veileder
Tilgjengelig fra: 2018-11-19 Laget: 2018-11-16 Sist oppdatert: 2019-02-07bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstScopus

Personposter BETA

Khan, Saad AhmedLundberg, JanStenström, Christer

Søk i DiVA

Av forfatter/redaktør
Khan, Saad AhmedLundberg, JanStenström, Christer
Av organisasjonen
I samme tidsskrift
Proceedings of the Institution of mechanical engineers. Part F, journal of rail and rapid transit

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 89 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf