The tale of an intake vortex and its mitigation countermeasure: A case study from akkats hydropower station
Vattenfall AB Research and Development, Älvkarleby Laboratory.
Luleå tekniska universitet, Institutionen för teknikvetenskap och matematik, Strömningslära och experimentell mekanik. Vattenfall AB Research and Development, Älvkarleby Laboratory.
Vattenfall AB Research and Development, Älvkarleby Laboratory.
Division of Resources, Energy and Infrastructure, Royal Institute of Technology.
2018 (engelsk)Inngår i: Water, E-ISSN 2073-4441, Vol. 10, nr 7, artikkel-id 881Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

The upgrade of Akkats power station in Sweden included a new, separate waterway for the addition of a 75 MW generating unit. The vertical intake of its headrace was formed by means of lake tapping. A physical model was used to help understand the blasting process involving fragmented rock, water, air, and gas. Upon commissioning of the unit, swirling flows occurred unexpectedly at the intake, which gave rise to negative consequences including limitations in power output. Echo-sounding showed that the blasted piercing resulted in an irregular intake. A hydraulic model, as part of the design process, was built to examine potential countermeasures for vortex suppression. The final solution was a segmented barrier between the intake and the dam. It effectively suppressed the intake flow circulations; only minor intermittent vortices were left. The fabricated steel segments were anchored into the bedrock, stretching to 1.0 m below the lowest legal reservoir level. The local intake headloss was also reduced. The implemented solution was tested under full turbine loading and the result was satisfactory. Even during winter seasons with ice cover above the wall, the power station ran normally. The case study is expected to provide guidance for solving similar problems with vortex formation.

sted, utgiver, år, opplag, sider
Basel: MDPI, 2018. Vol. 10, nr 7, artikkel-id 881
HSV kategori
Forskningsprogram
Strömningslära
Identifikatorer
URN: urn:nbn:se:ltu:diva-70324DOI: 10.3390/w10070881ISI: 000442579700064Scopus ID: 2-s2.0-85049645374OAI: oai:DiVA.org:ltu-70324DiVA, id: diva2:1237892
Merknad

Validerad;2018;Nivå 2;2018-08-10 (andbra)

Tilgjengelig fra: 2018-08-10 Laget: 2018-08-10 Sist oppdatert: 2025-02-09bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstScopus

Person

Andreasson, Patrik

Søk i DiVA

Av forfatter/redaktør
Andreasson, Patrik
Av organisasjonen
I samme tidsskrift
Water

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 108 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf