Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Experimental and Numerical Study of Moisture-induced Stress Formation in Hexagonal Glulam Using X-ray Computed Tomography and Finite-element Analysis
Nanjing Forestry University, College of Furnitures & Industrial Design, Nanjing.
Nanjing Forestry University, College of Material Science & Engineering, Nanjing.
Nanjing Forestry University, College of Furnitures & Industrial Design, Nanjing.
Luleå tekniska universitet, Institutionen för teknikvetenskap och matematik, Träteknik.ORCID-id: 0000-0002-0145-080x
Vise andre og tillknytning
2018 (engelsk)Inngår i: BioResources, ISSN 1930-2126, E-ISSN 1930-2126, Vol. 13, nr 4, s. 7395-7403Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Hexagonal glue-laminated timber with large cross-sections, made from small diameter logs, was studied. Effects of relative humidity variations on the moisture-induced stresses were investigated to evaluate how the prediction model compared to a real outcome. The test samples were exposed to an environment with relative humidity variations from 80% to 30%. The moisture content inside the samples was measured via X-ray computed tomography scanning. A moisture transport and a hygromechanical finite element simulation model was used for the prediction of moisture content and resulting stress distribution. The results from both the test and simulation showed that the moisture content in the edge angles of the samples dropped rapidly due to a large moisture diffusion rate. The moisture gradient was generated via a different moisture transfer rate at the inner and external parts of the samples. The maximum stress perpendicular to the grain in the simulation was 8 MPa and was located at the surface near the corners. This stress peak caused cracking according to the model, which was also seen in the test samples. The results for the measured moisture content agreed with the simulated results and this indicated that the moisture transfer model was adequate for simulation.

sted, utgiver, år, opplag, sider
University of North Carolina Press, 2018. Vol. 13, nr 4, s. 7395-7403
HSV kategori
Forskningsprogram
Träteknik
Identifikatorer
URN: urn:nbn:se:ltu:diva-70605DOI: 10.15376/biores.13.4.7395-7403ISI: 000454215100018OAI: oai:DiVA.org:ltu-70605DiVA, id: diva2:1242091
Merknad

Validerad;2018;Nivå 2;2018-08-27 (andbra)

Tilgjengelig fra: 2018-08-27 Laget: 2018-08-27 Sist oppdatert: 2019-01-29bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekst

Personposter BETA

Ekevad, Mats

Søk i DiVA

Av forfatter/redaktør
Ekevad, MatsWang, Alice
Av organisasjonen
I samme tidsskrift
BioResources

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 93 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf