Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Nano-fluid flow in a catheterized tapered artery: Consistent couple stress-theory and wall slip
Department of Mechanical Engineering, Shahrekord University, Shahrekord, Iran.
Department of Mechanical Engineering, Shahrekord University, Shahrekord, Iran.
Luleå tekniska universitet, Institutionen för teknikvetenskap och matematik, Strömningslära och experimentell mekanik.ORCID-id: 0000-0001-5294-1855
Department of Mechanical Engineering, Shahrekord University, Shahrekord, Iran.
2019 (engelsk)Inngår i: Journal of thermal analysis and calorimetry (Print), ISSN 1388-6150, E-ISSN 1588-2926, Vol. 137, nr 1, s. 327-342Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

This study was conducted with the aim of investigating the Newtonian nanofluid flow in a catheterized tapered artery through using a completely consistent couple stress theory. In the process of carrying out this study, the slip condition at the arterial wall and the catheter, as well as, the permeability was taken into account. Further, the velocity, temperature, and concentration profiles were analytically modeled and the effect of the length scale on these profiles was well presented through the way it influences small-scale flows. The effect of the slip condition at the artery and catheter walls on the velocity was also investigated and revealed that any increase in the velocity leads to an increase in the slip velocity. Furthermore, the effect of other parameters such as the catheter diameter, shape, and height of the stenosis on these profiles was explored for all three artery geometries, i.e., diverging tapered artery, converging tapered artery, and non-tapered artery, respectively. The findings suggested that any increase in the catheter diameter and stenosis height can decrease the velocity and nanoparticle concentration profiles, while the temperature profile increases. It was also found that by increasing the stenosis shape parameter the velocity and concentration profiles increase and temperature decreases.

sted, utgiver, år, opplag, sider
Springer, 2019. Vol. 137, nr 1, s. 327-342
Emneord [en]
Catheterized artery, Couple stress, Nanofluid, Slip velocity, Galerkin method
HSV kategori
Forskningsprogram
Strömningslära
Identifikatorer
URN: urn:nbn:se:ltu:diva-71601DOI: 10.1007/s10973-018-7930-3ISI: 000470338100029Scopus ID: 2-s2.0-85057847415OAI: oai:DiVA.org:ltu-71601DiVA, id: diva2:1263482
Merknad

Validerad;2019;Nivå 2;2019-07-01 (johcin)

Tilgjengelig fra: 2018-11-15 Laget: 2018-11-15 Sist oppdatert: 2025-02-09bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstScopus

Person

Westerberg, Lars-Göran

Søk i DiVA

Av forfatter/redaktør
Westerberg, Lars-Göran
Av organisasjonen
I samme tidsskrift
Journal of thermal analysis and calorimetry (Print)

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 356 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf