Voltage Sag Source Location Methods' Performance during Transient and Steady-state Periods
Luleå tekniska universitet, Institutionen för teknikvetenskap och matematik, Energivetenskap.ORCID-id: 0000-0001-8660-5569
Luleå tekniska universitet, Institutionen för teknikvetenskap och matematik, Energivetenskap.ORCID-id: 0000-0003-4074-9529
2022 (engelsk)Inngår i: 2022 20th International Conference on Harmonics & Quality of Power (ICHQP) Proceedings: “Power Quality in the Energy Transition”, IEEE, 2022Konferansepaper, Publicerat paper (Fagfellevurdert)
Abstract [en]

Online locating of voltage sag sources requires fast and accurate methods. In this context, this paper describes and compares the positive-sequence phasor-based (PB) and instantaneous-based (IB) methods during both transient and steady-state periods of voltage sags caused by grid faults and transformer energizing (TE). The methods are evaluated by applying 1992 voltage sags in a Brazilian power network. For fault cases, PB methods work better than IB. Some methods perform well within the transient period, and some do not work good enough and need improvements for online applications. For TE cases, IB methods are ahead of PB and most IB methods work very well in a half-cycle window of the transient period, whereas the PB methods must be improved. Regardless of the sag sources, the real current component method using IB values during the half-cycle window of transient period is the best method currently available, which can be used in online applications.

sted, utgiver, år, opplag, sider
IEEE, 2022.
Serie
International Conference on Harmonics and Quality of Power, ISSN 1540-6008, E-ISSN 2164-0610
Emneord [en]
voltage sag (dip), source location, transient period, steady-state period
HSV kategori
Forskningsprogram
Elkraftteknik
Identifikatorer
URN: urn:nbn:se:ltu:diva-92115DOI: 10.1109/ICHQP53011.2022.9808649ISI: 000844604500066Scopus ID: 2-s2.0-85133775551OAI: oai:DiVA.org:ltu-92115DiVA, id: diva2:1682011
Konferanse
20th International Conference on Harmonics & Quality of Power (ICHQP 2022), Naples, Italy, May 29 - June 1, 2022
Merknad

ISBN för värdpublikation: 978-1-6654-1639-9

Tilgjengelig fra: 2022-07-08 Laget: 2022-07-08 Sist oppdatert: 2022-09-19bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstScopus

Person

Mohammadi, YounesBollen, Math H. J.

Søk i DiVA

Av forfatter/redaktør
Mohammadi, YounesBollen, Math H. J.
Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 36 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf