Influence of natural convection in water-filled boreholes for GCHP
Luleå tekniska universitet, Institutionen för samhällsbyggnad och naturresurser, Arkitektur och vatten.
Swedish Society of HVAC Engineers, Stockholm.
2008 (engelsk)Inngår i: ASHRAE Transactions, ISSN 0001-2505, Vol. 114, nr 1, s. 416-423Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

In groundwater filled borehole heat exchangers (BHE), convective flow inside the borehole water will affect the heat transfer. Since the convective flow is dependent of the temperature gradient, different injection rates and ground temperatures will result in different borehole thermal resistance. This paper describes the influence of natural convection in water-filled boreholes in impermeable bedrock for ground-coupled heat pump (GCHP) systems. An overview of groundwater-filled boreholes and the influence of groundwater movements are presented followed by numerical simulations and field measurements to further investigate the influence. The results from the simulations of the three-dimensional, steady-state model of a 9.8 ft (3 m) deep BHE are compared to evaluated results from performed thermal response test (TRT). The results show that convective flow in groundwater-filled BHE results in 5-9 times more efficient heat transfer compared to stagnant water when heat carrier temperatures are in the range of 50-86°F (10-30°C). The size of the convective flow depends on the temperature gradients in the borehole. This shows the importance of on-site investigation of thermal properties using appropriate power injection rates similar to those in the system to be built. This research is part of an on-going project to find ways to estimate the heat transfer including convective flow and to incorporate the findings into the design of GCHP systems. TRT are today a common way to determine heat transfer properties for a BHE and its surroundings. Performing TRT measurements with several injection rates is a way to evaluate the dynamic thermal response including the change in convective flow due to changes in temperature levels. If this dynamic response would be included in design tools a more thorough design of the BHE system is performed. Here, the early result of this research is presented

sted, utgiver, år, opplag, sider
2008. Vol. 114, nr 1, s. 416-423
HSV kategori
Forskningsprogram
Vattenteknik; VA-teknik
Identifikatorer
URN: urn:nbn:se:ltu:diva-3765Scopus ID: 2-s2.0-55849091736Lokal ID: 198cd69f-ef6e-4bb9-ae5b-7ca88659b545OAI: oai:DiVA.org:ltu-3765DiVA, id: diva2:976626
Konferanse
Winter meeting of the American Society of Heating, Refrigerating and Air-Conditioning Engineers : 19/01/2008 - 23/01/2008
Merknad

Godkänd; 2008; 20110214 (andbra)

Tilgjengelig fra: 2016-09-29 Laget: 2016-09-29 Sist oppdatert: 2023-10-06bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Scopus

Person

Gustafsson, Anna-Maria

Søk i DiVA

Av forfatter/redaktør
Gustafsson, Anna-Maria
Av organisasjonen
I samme tidsskrift
ASHRAE Transactions

Søk utenfor DiVA

GoogleGoogle Scholar

urn-nbn

Altmetric

urn-nbn
Totalt: 182 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf