Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Determination of metal-humic complexes, free metal ions and total concentrations in natural waters
Luleå tekniska universitet.
1999 (engelsk)Inngår i: Journal of Environmental Monitoring, ISSN 1464-0325, E-ISSN 1464-0333, Vol. 1, nr 3, s. 211-7Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

A comparison of two systems for the quantitation of metal-humic complexes and free metal ions, consisting of the separation by coupled ion exchange columns followed by detection by inductively coupled plasma mass spectrometry or cold vapour atomic fluorescence spectrometry, is presented. The systems evaluated comprised the serially coupled anion and cation exchangers, Sephadex A-25/Chelex 100 and Dowex 1X8/Chelamine Metalfix. Separation and preconcentration of the species studied were accomplished with both systems, elution being carried out using 2 M HNO3. Total concentrations, metal-humic complex fractions and free metal ion fractions of Al, Ba, Cd, Co, Cu, Fe, Hg, Mn, Pb, Sr, U and Zn in nine natural waters were determined. Statistical evaluation of the data from the two cation exchange materials, including results for additional elements, showed better precision (for Al, Ba, Cr, Cu and Mo) and higher recoveries (Al, Ba, Cd, Fe, Sr and Zn) for Chelex 100 than Chelamine Metalfix for free metal ions. On the other hand, Chelamine Metalfix recovered a significantly greater amount of Ni. The amounts of metal-humic complexes were compared with modelled distributions of these species, and one advantage of the preferred Sephadex A-25/Chelex 100 system is that the elements studied are all correctly classified with respect to their binding strengths to humic substances, which is not the case with the Dowex 1X8/Chelamine Metalfix pair. With the preferred system, metal-humic complexes can be reliably determined, as indicated by the results of equilibrium speciation modelling. However, comparison with the total concentrations showed statistically significant, non-quantitative recoveries of Al, Cu, Hg, Mn, U and Zn from some samples. Thus a combination of speciation and total concentration measurements is required to obtain a complete representation of the distribution of trace elements in natural waters.

sted, utgiver, år, opplag, sider
1999. Vol. 1, nr 3, s. 211-7
HSV kategori
Forskningsprogram
Gränsytors kemi
Identifikatorer
URN: urn:nbn:se:ltu:diva-5885Lokal ID: 4131e7b0-78bb-11dd-955a-000ea68e967bOAI: oai:DiVA.org:ltu-5885DiVA, id: diva2:978761
Merknad
Godkänd; 1999; 20080902 (andbra)Tilgjengelig fra: 2016-09-29 Laget: 2016-09-29 Sist oppdatert: 2017-11-24bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Personposter BETA

Baxter, Douglas

Søk i DiVA

Av forfatter/redaktør
Baxter, Douglas
I samme tidsskrift
Journal of Environmental Monitoring

Søk utenfor DiVA

GoogleGoogle Scholar

urn-nbn

Altmetric

urn-nbn
Totalt: 42 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf