Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Comparison of Goldmann applanation and applanation resonance tonometry in a biomicroscope-based in vitro porcine eye model
Umeå University Hospital, Department of Biomedical Engineering & Informatics.
Umeå University, Department of Clinical Science, Ophthalmology.
Umeå University, Centre for Biomedical Engineering and Physics.
Vise andre og tillknytning
2006 (engelsk)Inngår i: Journal of Medical Engineering & Technology, ISSN 0309-1902, E-ISSN 1464-522X, Vol. 30, nr 6, s. 345-52Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

We have developed an in vitro porcine eye model based on a biomicroscope, to simulate a clinical situation for IOP measurement on enucleated eyes. The aims of this study were to evaluate the model and to apply and compare Goldmann applanation tonometry (GAT) and applanation resonance tonometry (ART) measurements in porcine eyes. The GAT measurement (IOPGAT) showed a lower pressure, mean - 14.0 mm Hg (SD = 1.7 mm Hg) as compared with the reference pressure. For in vitro measurement with GAT on porcine eyes the linear calibration was IOP = 1.14 IOPGAT + 12.5 mm Hg (R2 = 0.99, p < 0.001, n = 280, four eyes). ART measurements correlated significantly to reference IOP, R = 0.86 (p < 0.001, n = 252, six eyes), with a mean difference of 5.4 mm Hg (SD = 6.7 mm Hg). GAT could only be used on porcine eyes if the IOP exceeded 13 mm Hg. Evaluation of the ART in this in vitro model showed position dependence for the sensor. To facilitate centre positioning a guiding tool is suggested. Porcine eyes are a possible substitute for human eyes in in vitro models for pre-clinical evaluation of new tonometry methods.

sted, utgiver, år, opplag, sider
2006. Vol. 30, nr 6, s. 345-52
HSV kategori
Forskningsprogram
Medicinsk teknik för hälsovård
Identifikatorer
URN: urn:nbn:se:ltu:diva-6295DOI: 10.1080/03091900512331332528Lokal ID: 4818ee30-0f61-11dc-b9dd-000ea68e967bOAI: oai:DiVA.org:ltu-6295DiVA, id: diva2:979172
Merknad
Upprättat; 2006; 20070531 (andbra)Tilgjengelig fra: 2016-09-29 Laget: 2016-09-29 Sist oppdatert: 2017-11-24bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekst

Personposter BETA

Lindahl, Olof

Søk i DiVA

Av forfatter/redaktør
Lindahl, Olof
I samme tidsskrift
Journal of Medical Engineering & Technology

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 86 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf