Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Distributed generation and the voltage profile on distribution feeders during voltage dips
Electrical Energy Laboratory (EELAB), Department of Electrical Energy, Systems and Automation (EESA), Ghent University, Gent, Belgium.
Electrical Energy Laboratory (EELAB), Department of Electrical Energy, Systems and Automation (EESA), Ghent University, Gent, Belgium.
Electrical Energy Laboratory (EELAB), Department of Electrical Energy, Systems and Automation (EESA), Ghent University, Gent, Belgium.
Electrical Energy Laboratory (EELAB), Department of Electrical Energy, Systems and Automation (EESA), Ghent University, Gent, Belgium;Provinciale Industriële Hogeschool, Hogeschool West-Vlaanderen, Kortrijk, Belgium.
Vise andre og tillknytning
2010 (engelsk)Inngår i: Electric power systems research, ISSN 0378-7796, E-ISSN 1873-2046, Vol. 80, nr 12, s. 1452-1458Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

The presence of distributed generators in the distribution network results in an increase of the voltage magnitude close to these generators, during a fault elsewhere in the distribution system or in the transmission system. This voltage dip mitigation capability of converter-connected distributed generation (DG) units is dependent on the control strategy of the converter. To compare the influence of different types of converter-connected distributed generators on the voltage profile along distribution feeders during a fault, the quantity,"voltage ratio" is used. This voltage ratio is obtained by division of the voltage during the voltage dip by the voltage just before the voltage dip. The different converter types are modelled, and the influence on the voltage ratio is analysed.

sted, utgiver, år, opplag, sider
2010. Vol. 80, nr 12, s. 1452-1458
Emneord [en]
Voltage dips, Power quality, Distributed generation, Low-voltage grids
HSV kategori
Forskningsprogram
Elkraftteknik; Energiteknik
Identifikatorer
URN: urn:nbn:se:ltu:diva-10319DOI: 10.1016/j.epsr.2010.06.012ISI: 000282404500009Scopus ID: 2-s2.0-77956343859Lokal ID: 91c23930-981e-11df-8806-000ea68e967bOAI: oai:DiVA.org:ltu-10319DiVA, id: diva2:983261
Merknad

Validerad; 2010; 20100725 (ysko)

Tilgjengelig fra: 2016-09-29 Laget: 2016-09-29 Sist oppdatert: 2022-04-01bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstScopus

Person

Bollen, Math H. J.

Søk i DiVA

Av forfatter/redaktør
Bollen, Math H. J.
Av organisasjonen
I samme tidsskrift
Electric power systems research

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 26 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf