Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Nano-fluid flow in a catheterized tapered artery: Consistent couple stress-theory and wall slip
Department of Mechanical Engineering, Shahrekord University, Shahrekord, Iran.
Department of Mechanical Engineering, Shahrekord University, Shahrekord, Iran.
Luleå tekniska universitet, Institutionen för teknikvetenskap och matematik, Strömningslära och experimentell mekanik.ORCID-id: 0000-0001-5294-1855
Department of Mechanical Engineering, Shahrekord University, Shahrekord, Iran.
2019 (Engelska)Ingår i: Journal of thermal analysis and calorimetry (Print), ISSN 1388-6150, E-ISSN 1588-2926, Vol. 137, nr 1, s. 327-342Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

This study was conducted with the aim of investigating the Newtonian nanofluid flow in a catheterized tapered artery through using a completely consistent couple stress theory. In the process of carrying out this study, the slip condition at the arterial wall and the catheter, as well as, the permeability was taken into account. Further, the velocity, temperature, and concentration profiles were analytically modeled and the effect of the length scale on these profiles was well presented through the way it influences small-scale flows. The effect of the slip condition at the artery and catheter walls on the velocity was also investigated and revealed that any increase in the velocity leads to an increase in the slip velocity. Furthermore, the effect of other parameters such as the catheter diameter, shape, and height of the stenosis on these profiles was explored for all three artery geometries, i.e., diverging tapered artery, converging tapered artery, and non-tapered artery, respectively. The findings suggested that any increase in the catheter diameter and stenosis height can decrease the velocity and nanoparticle concentration profiles, while the temperature profile increases. It was also found that by increasing the stenosis shape parameter the velocity and concentration profiles increase and temperature decreases.

Ort, förlag, år, upplaga, sidor
Springer, 2019. Vol. 137, nr 1, s. 327-342
Nyckelord [en]
Catheterized artery, Couple stress, Nanofluid, Slip velocity, Galerkin method
Nationell ämneskategori
Strömningsmekanik
Forskningsämne
Strömningslära
Identifikatorer
URN: urn:nbn:se:ltu:diva-71601DOI: 10.1007/s10973-018-7930-3ISI: 000470338100029Scopus ID: 2-s2.0-85057847415OAI: oai:DiVA.org:ltu-71601DiVA, id: diva2:1263482
Anmärkning

Validerad;2019;Nivå 2;2019-07-01 (johcin)

Tillgänglig från: 2018-11-15 Skapad: 2018-11-15 Senast uppdaterad: 2025-02-09Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextScopus

Person

Westerberg, Lars-Göran

Sök vidare i DiVA

Av författaren/redaktören
Westerberg, Lars-Göran
Av organisationen
Strömningslära och experimentell mekanik
I samma tidskrift
Journal of thermal analysis and calorimetry (Print)
Strömningsmekanik

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 356 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf