Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Modelling of air demands of a spillway aerator with two-phase flow models
Division of Resources, Energy & Infrastructure, Royal Institute of Technology (KTH), Stockholm, SwedenDivision of Resources, Energy & Infrastructure, Royal Institute of Technology (KTH), Stockholm, Sweden. Vattenfall R&D, Älvkarleby Hydraulic Laboratory, Älvkarleby, Sweden.
Division of Resources, Energy & Infrastructure, Royal Institute of Technology (KTH), Stockholm, Sweden.
Luleå tekniska universitet, Institutionen för teknikvetenskap och matematik, Strömningslära och experimentell mekanik.ORCID-id: 0000-0003-0820-617X
2018 (Engelska)Ingår i: E-proceedings of the 2nd International Symposium on Hydraulic Modelling and Measuring Technology Congress, International Association for Hydro-Enviroment Engineering and Research (IAHR) , 2018Konferensbidrag, Publicerat paper (Refereegranskat)
Abstract [en]

Air demand is an issue of concern for a spillway aerator. To numerically map its air-water flow behavior has a bearing on its design. The recently completed spillway at Bergeforsen features a 35-m wide chute aerator with 13 air vents. With this in background, CFD modelling is performed with three commonly used two-phase flow models, i.e. the Volume-of-Fluid (VOF) Model, Two-Fluid Model and Mixture Model. The purpose is to evaluate these models in terms of water-air flow properties. The simulations have shown that the VOF Model generates the lowest air demand, while the Two-Fluid Model points to a 34% higher value, which is attributable to the differences in the two-phase flow formulations. The resulting air pressure in the air cavity including the air groove leads also to considerable discrepancy in the vent air-flow distribution across the chute and spatial air concentration. Evaluations of two-phase models are necessary, so that a reliable model is adopted for engineering design.

Ort, förlag, år, upplaga, sidor
International Association for Hydro-Enviroment Engineering and Research (IAHR) , 2018.
Nyckelord [en]
spillway, aerator, air demand, two-phase model
Nationell ämneskategori
Strömningsmekanik och akustik
Forskningsämne
Strömningslära
Identifikatorer
URN: urn:nbn:se:ltu:diva-72716OAI: oai:DiVA.org:ltu-72716DiVA, id: diva2:1283235
Konferens
Second International Symposium on Hydraulic Modelling and Measuring Technology, 30 May-1 June, 2018, Nanjing, China
Tillgänglig från: 2019-01-28 Skapad: 2019-01-28 Senast uppdaterad: 2022-06-01Bibliografiskt granskad

Open Access i DiVA

fulltext(1054 kB)55 nedladdningar
Filinformation
Filnamn FULLTEXT01.pdfFilstorlek 1054 kBChecksumma SHA-512
c09739a95e58312b2e569c983d5e7b06f7d6c16ec14edb6d8e85666f69ce43df5a1b84dd7721ef9840435c0887b48859ca1f6edf3569c4b9d9fd40604bfbd201
Typ fulltextMimetyp application/pdf

Person

Xie, Qiancheng

Sök vidare i DiVA

Av författaren/redaktören
Xie, Qiancheng
Av organisationen
Strömningslära och experimentell mekanik
Strömningsmekanik och akustik

Sök vidare utanför DiVA

GoogleGoogle Scholar
Totalt: 55 nedladdningar
Antalet nedladdningar är summan av nedladdningar för alla fulltexter. Det kan inkludera t.ex tidigare versioner som nu inte längre är tillgängliga.

urn-nbn

Altmetricpoäng

urn-nbn
Totalt: 72 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf