An analysis of voltage quality in a nanogrid during islanded operation
Luleå tekniska universitet, Institutionen för teknikvetenskap och matematik, Energivetenskap.ORCID-id: 0000-0003-1894-6980
Luleå tekniska universitet, Institutionen för teknikvetenskap och matematik, Energivetenskap.ORCID-id: 0000-0002-4004-0352
Luleå tekniska universitet, Institutionen för teknikvetenskap och matematik, Energivetenskap.ORCID-id: 0000-0003-4074-9529
2019 (Engelska)Ingår i: Energies, E-ISSN 1996-1073, Vol. 12, nr 4, artikel-id 614Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Voltage quality data has been collected in a single house nanogrid during 48 weeks of islanded operation and 54 weeks of grid-connected operation. The voltage quality data contains the voltage total harmonic distortion (THD), odd harmonics 3 to 11 and 15, even harmonics 4 to 8, voltage unbalance, short-term flicker severity (Pst) and long-term flicker severity (Plt) values, and voltage variations at timescales below 10 min. A comparison between islanded and grid-connected operation values was made, were some of the parameters were compared to relevant grid standard limits. It is shown that some parameters exceed the defined limits in the grid-standards during islanded operation. It was also found that the islanded operation has two modes of operation, one in which higher values of the short circuit impedance, individual harmonic impedance, harmonic voltage distortion and voltage unbalance were reached.

Ort, förlag, år, upplaga, sidor
MDPI, 2019. Vol. 12, nr 4, artikel-id 614
Nyckelord [en]
harmonics, islanded operation, nanogrids, power quality, voltage unbalance
Nationell ämneskategori
Annan elektroteknik och elektronik
Forskningsämne
Elkraftteknik
Identifikatorer
URN: urn:nbn:se:ltu:diva-73155DOI: 10.3390/en12040614ISI: 000460667700040Scopus ID: 2-s2.0-85061970485OAI: oai:DiVA.org:ltu-73155DiVA, id: diva2:1295205
Anmärkning

Validerad;2019;Nivå 2;2019-03-11 (johcin)

Tillgänglig från: 2019-03-11 Skapad: 2019-03-11 Senast uppdaterad: 2023-09-05Bibliografiskt granskad
Ingår i avhandling
1. Power quality analysis and techno-economic modeling for microgrids
Öppna denna publikation i ny flik eller fönster >>Power quality analysis and techno-economic modeling for microgrids
2021 (Engelska)Doktorsavhandling, sammanläggning (Övrigt vetenskapligt)
Abstract [en]

The work done in this thesis considers microgrids from two different aspects. Power quality and techno-economics of microgrids. Detailed power quality measurements have been made at a single house hydrogen-solar microgrid that consists of state-of-the-art energy efficiency technology, energy production and energy storage. The microgrid can both connect to the grid and operate in islanded operation. The power quality is quantified from these measurements where several power quality parameters during islanded operation go beyond the limits set by standards such as EN 50160 and IEEE 519-2014. The effect on connected equipment from both frequency variations and voltage quality is also discussed. Four new performance indexes are presented in the thesis that are based on apparent impedances. The first with the name PHIPI quantifies how much the harmonic voltage magnitude changes with an increase in harmonic current magnitude on the same phase. The second with the name SHIPI quantifies how much the harmonic voltage magnitude changes with an increase in harmonic current magnitude on another phase. The third with the name AHSI uses the harmonic voltage and current magnitudes of all phases to create a single performance parameter expressed as an apparent impedance for the system. The fourth with the name ARMSSI quantifies the phase RMS voltage drop for a certain phase RMS current rise in terms of an apparent impedance. The thesis also shows techno-economic modeling with times series energy flow to study the investment risks related to consumption changes in a standalone microgrid. The results show that consumption changes are an important parameter when designing a standalone microgrid and that the risk can be mitigated with changes to the system design, but at a larger system cost. The projected cost reduction until the year 2050 for standalone hydrogen based microgrids and some risk aspects with hydrogen based microgrids are also discussed in the thesis. 

Ort, förlag, år, upplaga, sidor
Luleå: Luleå University of Technology, 2021
Serie
Doctoral thesis / Luleå University of Technology 1 jan 1997 → …, ISSN 1402-1544
Nyckelord
Power Quality, Economy, Microgrids
Nationell ämneskategori
Energiteknik
Forskningsämne
Elkraftteknik
Identifikatorer
urn:nbn:se:ltu:diva-87616 (URN)978-91-7790-966-8 (ISBN)978-91-7790-967-5 (ISBN)
Disputation
2021-12-13, Hörsal A and online, Skellefteå, 10:00 (Engelska)
Opponent
Handledare
Tillgänglig från: 2021-10-25 Skapad: 2021-10-25 Senast uppdaterad: 2023-09-05Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextScopus

Person

Nömm, JakobRönnberg, SarahBollen, Math

Sök vidare i DiVA

Av författaren/redaktören
Nömm, JakobRönnberg, SarahBollen, Math
Av organisationen
Energivetenskap
I samma tidskrift
Energies
Annan elektroteknik och elektronik

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 309 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf