Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Tanks in series model with dynamic shortcut flows for a straight tundish. Verification by tracer experiments on production heats
Luleå tekniska universitet. SSAB Tunnplåt AB, Luleå, Sweden.ORCID-id: 0000-0001-8247-8320
Luleå tekniska universitet.
SSAB Tunnplåt AB, Luleå, Sweden.
SSAB, Sweden; MEFOS, Sweden.
1998 (Engelska)Ingår i: High Temperature Materials and Processes, ISSN 0334-6455, E-ISSN 2191-0324, Vol. 17, nr 3, s. 177-192Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Production control must have accurate models for the prediction of tundish temperature to meet increasing demands on control and production rate in continuous casting. The models have to be simple. They must also include the effect of variations in steel flow and mixing, including shortcut flows from the inlet stream towards the outlet end. To meet this demand, a tank in series model was designed, which also included the effect of dynamic shortcut flows. The model has been verified by data from experiments with chemical tracers in a 14 tonne straight tundish. The tracers have been added both in the ladle and close to the inlet end in the tundish and the response in the steel entering the mould has been died. The data seem to confirm that there is a different distribution of the steel flow in the period shortly after the ladle change. The difference could be explained either as shortcut flows caused by buoyancy or by increased stirring. It is possible to choose a configuration of tanks that allows simulation of both the transient behaviour at ladle change and the steady state conditions during the main part of the casting by changing the adjustable parameters for the shortcut flow without changing the configuration of tanks.

Ort, förlag, år, upplaga, sidor
1998. Vol. 17, nr 3, s. 177-192
Nationell ämneskategori
Energiteknik
Forskningsämne
Energiteknik
Identifikatorer
URN: urn:nbn:se:ltu:diva-4298DOI: 10.1515/HTMP.1998.17.3.177Scopus ID: 2-s2.0-0032118326Lokalt ID: 23aa81c0-0ba1-11dd-9b51-000ea68e967bOAI: oai:DiVA.org:ltu-4298DiVA, id: diva2:977162
Anmärkning

Godkänd; 1998; 20080416 (cira)

Tillgänglig från: 2016-09-29 Skapad: 2016-09-29 Senast uppdaterad: 2021-12-29Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextScopus

Person

Grip, Carl-Erik

Sök vidare i DiVA

Av författaren/redaktören
Grip, Carl-Erik
Av organisationen
Luleå tekniska universitet
I samma tidskrift
High Temperature Materials and Processes
Energiteknik

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 62 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf