Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Distributed generation and the voltage profile on distribution feeders during voltage dips
Electrical Energy Laboratory (EELAB), Department of Electrical Energy, Systems and Automation (EESA), Ghent University, Gent, Belgium.
Electrical Energy Laboratory (EELAB), Department of Electrical Energy, Systems and Automation (EESA), Ghent University, Gent, Belgium.
Electrical Energy Laboratory (EELAB), Department of Electrical Energy, Systems and Automation (EESA), Ghent University, Gent, Belgium.
Electrical Energy Laboratory (EELAB), Department of Electrical Energy, Systems and Automation (EESA), Ghent University, Gent, Belgium;Provinciale Industriële Hogeschool, Hogeschool West-Vlaanderen, Kortrijk, Belgium.
Visa övriga samt affilieringar
2010 (Engelska)Ingår i: Electric power systems research, ISSN 0378-7796, E-ISSN 1873-2046, Vol. 80, nr 12, s. 1452-1458Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

The presence of distributed generators in the distribution network results in an increase of the voltage magnitude close to these generators, during a fault elsewhere in the distribution system or in the transmission system. This voltage dip mitigation capability of converter-connected distributed generation (DG) units is dependent on the control strategy of the converter. To compare the influence of different types of converter-connected distributed generators on the voltage profile along distribution feeders during a fault, the quantity,"voltage ratio" is used. This voltage ratio is obtained by division of the voltage during the voltage dip by the voltage just before the voltage dip. The different converter types are modelled, and the influence on the voltage ratio is analysed.

Ort, förlag, år, upplaga, sidor
2010. Vol. 80, nr 12, s. 1452-1458
Nyckelord [en]
Voltage dips, Power quality, Distributed generation, Low-voltage grids
Nationell ämneskategori
Annan elektroteknik och elektronik Energiteknik
Forskningsämne
Elkraftteknik; Energiteknik
Identifikatorer
URN: urn:nbn:se:ltu:diva-10319DOI: 10.1016/j.epsr.2010.06.012ISI: 000282404500009Scopus ID: 2-s2.0-77956343859Lokalt ID: 91c23930-981e-11df-8806-000ea68e967bOAI: oai:DiVA.org:ltu-10319DiVA, id: diva2:983261
Anmärkning

Validerad; 2010; 20100725 (ysko)

Tillgänglig från: 2016-09-29 Skapad: 2016-09-29 Senast uppdaterad: 2022-04-01Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextScopus

Person

Bollen, Math H. J.

Sök vidare i DiVA

Av författaren/redaktören
Bollen, Math H. J.
Av organisationen
Energivetenskap
I samma tidskrift
Electric power systems research
Annan elektroteknik och elektronikEnergiteknik

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 26 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf