Analysis of a new plate thermometer: the copper disc plate thermometer
Luleå tekniska universitet, Institutionen för samhällsbyggnad och naturresurser, Byggkonstruktion och brand.ORCID-id: 0000-0002-3112-0270
Luleå tekniska universitet.
Luleå tekniska universitet.
Luleå tekniska universitet.
Vise andre og tillknytning
2015 (engelsk)Inngår i: Proceedings of the International Fire Safety Symposium 2015: Coimbra, Portugal, 20th-22nd April 2015 / [ed] João Paulo C Rodrigues, International Fire Safety Symposium , 2015, s. 453-460Konferansepaper, Publicerat paper (Fagfellevurdert)
Abstract [en]

Two temperatures govern heat transfer to a surface of a solid body. One is the gas temperature which can be measured with thermocouples (TC) and the other the black body radiation temperature. The latter can also be expressed as the incident radiant heat flux. It is difficult to measure as radiometers cannot be used under hot fire conditions. Indirectly the radiation temperature can be obtained by measuring the Adiabatic Surface Temperature (AST) with plate thermometers (PT) for example as defined in the fire resistance furnace standards EN 1363-1 and ISO-834-1 combined with measurements of gas temperature with thin TC. In the test reported here a smaller gauge is used to measure adiabatic surface temperature at surfaces. It has been named copper disc Plate Thermometer (cdPT). Then a thin copper disc with an attached TC is mounted flush at the surface to obtain the AST in e.g. cone calorimeters according to ISO 5660. A main advantage of the cdPT is that it can record the AST before as well after a material has ignited. It can thereby be used to indicate ignition as well as continue recording the thermal exposure thereafter when ignition occurs the cdPT reacts immediately by displaying a quick temperature rise.

sted, utgiver, år, opplag, sider
International Fire Safety Symposium , 2015. s. 453-460
HSV kategori
Forskningsprogram
Stålbyggnad
Identifikatorer
URN: urn:nbn:se:ltu:diva-31849Lokal ID: 627ae436-bebe-4e8d-a32a-f3aa18fcb34dOAI: oai:DiVA.org:ltu-31849DiVA, id: diva2:1005083
Konferanse
International Fire Safety Symposium : 20/04/2015 - 22/04/2015
Merknad
Godkänd; 2015; 20160823 (alebys)Tilgjengelig fra: 2016-09-30 Laget: 2016-09-30 Sist oppdatert: 2018-08-15bibliografisk kontrollert

Open Access i DiVA

fulltekst(1614 kB)133 nedlastinger
Filinformasjon
Fil FULLTEXT01.pdfFilstørrelse 1614 kBChecksum SHA-512
ddf61805f38934b55499045d03a353f7f883462eed990db3974783f523d1134391ff1bfb7bab782f91dcf9f4c64c50ebe108625b90fd11d2db9cd6eb252e4097
Type fulltextMimetype application/pdf

Personposter BETA

Byström, AlexandraWickström, Ulf

Søk i DiVA

Av forfatter/redaktør
Byström, AlexandraWickström, Ulf
Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 133 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

urn-nbn

Altmetric

urn-nbn
Totalt: 189 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf