Using fouggara for heating and cooling buildings in Sahara
Luleå University of Technology, Department of Civil, Environmental and Natural Resources Engineering, Architecture and Water.
Luleå University of Technology, Department of Civil, Environmental and Natural Resources Engineering, Architecture and Water.ORCID iD: 0000-0001-7144-9778
Unité de Recherche Matériaux et Energies Renouvelables (URMER), Université de Tlemcen, BP 119 Tlemcen, Algeria.
2011 (English)In: Energy Procedia, ISSN 1876-6102, Vol. 6, p. 55-64Article in journal (Refereed) Published
Abstract [en]

In order to utilise naturally stored heat or cold from the ground, seasonal temperature variations are required. The reason is that the ground temperature is then warmer than the air temperature during winter and colder during summer. The heating and cooling demand in North Africa varies considerably with the greatest cooling demand in the East and the greatest heating demand in the West. In parts of Algeria the mean temperature difference between the coldest and warmest month is greater than 20 °C, which is favourable. In current work it was shown that the ancient Fouggara system, even today would be interesting for heating and cooling of buildings in the Sahara desert.

Place, publisher, year, edition, pages
2011. Vol. 6, p. 55-64
National Category
Water Engineering
Research subject
Water Resources Engineering
Identifiers
URN: urn:nbn:se:ltu:diva-32665DOI: 10.1016/j.egypro.2011.05.007ISI: 000298294900007Scopus ID: 2-s2.0-79960235602Local ID: 738f415b-b283-428c-bb08-4a8e3bfa5dd5OAI: oai:DiVA.org:ltu-32665DiVA, id: diva2:1005899
Conference
Impact of Integrated Clean Energy on the Future of the Mediterranean Environment : 14/04/2011 - 16/04/2011
Note

Validerad;2011;20110620 (ysko);Konferensartikel i tidskrift;

License fulltext: CC BY-NC-ND;

For corrigendum, see: Amara., S. (2011). Corrigendum to “Using Fouggara for Heating and Cooling Buildings in Sahara” (Energy Procedia 6 (2011), 55–64). Energy Procedia, vol. 6, 2011, page 825. https://doi.org/10.1016/j.egypro.2012.03.001

Available from: 2016-09-30 Created: 2016-09-30 Last updated: 2023-10-24Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textScopus

Authority records

Amara, SofianeNordell, Bo

Search in DiVA

By author/editor
Amara, SofianeNordell, Bo
By organisation
Architecture and Water
In the same journal
Energy Procedia
Water Engineering

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 503 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf