Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Characterization of the thermal exposure in the en 50399 cable test apparatus
Luleå University of Technology, Department of Civil, Environmental and Natural Resources Engineering, Structural and Construction Engineering.ORCID iD: 0000-0002-7140-4737
SP Technical Research Institute of Sweden, Borås, SP Sveriges Tekniska Forskningsinstitut, Brandteknik.
Luleå University of Technology, Department of Civil, Environmental and Natural Resources Engineering, Structural and Construction Engineering.ORCID iD: 0000-0003-2181-2828
SP Technical Research Institute of Sweden, Borås.
Show others and affiliations
2015 (English)In: Fire and Materials 2015, 2-4 Feb 2015, San Francisco, USA: proceedings, Interscience Communications, 2015, p. 23-37Conference paper, Published paper (Refereed)
Abstract [en]

The EN 50399 cable test is used for classification of cables within the European construction products regulation. Means to predict a cables performance in this test, based on material data and small scale test results is of great value for the development of new cable materials. A first step in developing a prediction tool should be to understand the heat exposure on the cables in the EN 50399 test apparatus. The heat load in e.g. the cone calorimeter is very well characterized whereas for EN 50399 only the burner power (20.5 kW) is known. In the cone calorimeter the heating is solely by radiation, whereas for the EN 50399 test a large fraction of the heat exposure depends on feed-back from the cable fire. This paper presents a measuring method for characterizing the thermal exposure inside the EN 50399 cable test apparatus without cables and with a cable rated Euroclass Dca. A new instrument for measuring thermal exposure simultaneously in several directions was developed for the purpose, and thereby the non-isotropic exposure on the cables at different position on the ladder could be investigated

Place, publisher, year, edition, pages
Interscience Communications, 2015. p. 23-37
National Category
Building Technologies
Research subject
Steel Structures
Identifiers
URN: urn:nbn:se:ltu:diva-35234Scopus ID: 2-s2.0-84983109474Local ID: 9afad90d-0d48-499f-9f29-1d8f3de9d866ISBN: 9780000000002 (electronic)OAI: oai:DiVA.org:ltu-35234DiVA, id: diva2:1008486
Conference
International Conference and Exhibition on Fire and Materials : 02/02/2015 - 04/02/2015
Note
Godkänd; 2015; 20151125 (andbra)Available from: 2016-09-30 Created: 2016-09-30 Last updated: 2023-10-06Bibliographically approved

Open Access in DiVA

No full text in DiVA

Scopus

Authority records

Försth, MichaelWickström, Ulf

Search in DiVA

By author/editor
Försth, MichaelWickström, Ulf
By organisation
Structural and Construction Engineering
Building Technologies

Search outside of DiVA

GoogleGoogle Scholar

isbn
urn-nbn

Altmetric score

isbn
urn-nbn
Total: 1022 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf