Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Effect of light intensities variations on bulk curing of dental composites
Luleå tekniska universitet, Institutionen för teknikvetenskap och matematik, Maskinelement.ORCID-id: 0000-0001-8676-8819
Florida University.
Kungliga tekniska högskolan, KTH.
2002 (Engelska)Ingår i: Journal of Dental Research, ISSN 0022-0345, E-ISSN 1544-0591, Vol. 81, nr Suppl. 1Artikel i tidskrift, Meeting abstract (Refereegranskat) Published
Abstract [en]

The light intensity used during curing of light curable dental composites is believed to affect the residual stress level. In this study we tested the hypothesis that low light intensity and long but clinically acceptable light curing time, can produce composites with physical/clinical properties (e.g. volumetric shrinkage, linear contraction stress, degree of conversion (DC%) and Young's modulus) comparable to those of high light intensity cured composites. Methods: Two dental composites, Z100 and Z250, were investigated. Specimens were cured with light intensities of 200, 450 and 800 mW/cm2 for 140, 60 and 35 s from a distance of 7 mm. Linear contraction strains were measured with strain-gages attached to stainless steel rings serving as molds (8 mm in diameter and 4 mm high). DC% was measured at the top and the bottom of samples as well through the bulk using FTIR. Volumetric polymerization shrinkage was determined using a water displacement method. Young's modulus was determined in tension on composite specimens with dimensions of 8 x 50 x 1 mm. Results: Polymerization stress level decreased significantly (p<0.05) when cured with 200 mW/cm2 rather than with 800 mW/cm2. Reduction in light intensity did not decrease the DC% values significantly, nevertheless the most dramatic differences existed between top and bottom surfaces (p<0.05) rather than among curing groups. Measured modulus and volumetric shrinkage values were no significantly different (p>0.05) between different light intensity groups. Conclusion: Low light intensity decreased the residual stress and DC% values (through the depth of cure) significantly (p<0.05), but did not significantly affect the Young's modulus and the volumetric shrinkage values. The lower residual stress values, reflected by lower strain levels in the metal rings used during measurement, suggest that more stress relaxation occurs in the low light intensity group during cure. Our results support the proposed hypothesis

Ort, förlag, år, upplaga, sidor
2002. Vol. 81, nr Suppl. 1
Nationell ämneskategori
Tribologi (ytteknik omfattande friktion, nötning och smörjning)
Forskningsämne
Maskinelement
Identifikatorer
URN: urn:nbn:se:ltu:diva-37717DOI: 10.1177/0022034502081S101Lokalt ID: bd3546e0-f8a2-11df-8b95-000ea68e967bOAI: oai:DiVA.org:ltu-37717DiVA, id: diva2:1011215
Konferens
General Session of International Association for Dental Research : 06/03/2002 - 09/03/2002
Anmärkning
Godkänd; 2002; Bibliografisk uppgift: Winner of Edward Hatton Award competition; 20110310 (andbra)Tillgänglig från: 2016-10-03 Skapad: 2016-10-03 Senast uppdaterad: 2018-03-08Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltext

Personposter BETA

Emami, Nazanin

Sök vidare i DiVA

Av författaren/redaktören
Emami, Nazanin
Av organisationen
Maskinelement
I samma tidskrift
Journal of Dental Research
Tribologi (ytteknik omfattande friktion, nötning och smörjning)

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 42 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf