Thermal Exposure Caused by the Smoke Gas Layer in Pre-flashover Fires: A Two-zone Model Approach
Luleå tekniska universitet, Institutionen för samhällsbyggnad och naturresurser, Byggkonstruktion och brand.
2016 (engelsk)Independent thesis Basic level (university diploma), 10 poäng / 15 hpOppgave
Abstract [en]

A pre-flashover fire is very different from a post-flashover fire. The main difference is that in a pre-flashover fire the gas temperature and the radiation temperature differ. One thing that makes it a lot different is that the thermal exposure induced by a pre-flashover fire is largely affected by the smoke gas layer. These smoke gases can be very hot and therefore they emit heat radiation to their surroundings. The theory used, to calculate the thermal exposure of a pre-flashover fire, in this thesis relies on using thermal resistances to describe the heat transfer from the smoke gases. By doing so it is possible to calculate the temperatures of the smoke gases and the surfaces in touch with the smoke gases. Another approach is to use CFD software to numerically calculate the temperatures and in this thesis the two-zone model are compared to FDS, a CFD software. The two-zone model are also compared to a reduced-scale test. The comparisons gave good results, the two-zone model produced similar results compared to re reduced-scale test and FDS. This method of calculating thermal exposure can thereby be used to evaluate evacuation safety and save a lot of calculation time compared to calculating the thermal exposure with CFD software such as FDS.

sted, utgiver, år, opplag, sider
2016.
Emneord [en]
Thermal exposure, smoke gas layer, two-zone model
HSV kategori
Identifikatorer
URN: urn:nbn:se:ltu:diva-60971OAI: oai:DiVA.org:ltu-60971DiVA, id: diva2:1053169
Eksternt samarbeid
Tyréns
Utdanningsprogram
Fire Protection Engineer, bachelor's level
Veileder
Examiner
Tilgjengelig fra: 2016-12-13 Laget: 2016-12-08 Sist oppdatert: 2016-12-13bibliografisk kontrollert

Open Access i DiVA

fulltext(3677 kB)402 nedlastinger
Filinformasjon
Fil FULLTEXT02.pdfFilstørrelse 3677 kBChecksum SHA-512
ecdc207068953bb3c6481055ac707a877141e0f39d0ed18ad11fcdb89da4e1a8925e75860743a85d3858a0e733217c7dff38ff2aa9e1757f1b07eabca89a4f7c
Type fulltextMimetype application/pdf

Søk i DiVA

Av forfatter/redaktør
Andersson, Lucas
Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 402 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

urn-nbn

Altmetric

urn-nbn
Totalt: 839 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf