Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Dielectric Thermoscopy Characterization of Water Contaminated Grease
Luleå tekniska universitet, Institutionen för teknikvetenskap och matematik, Maskinelement.ORCID-id: 0000-0002-4857-9475
Luleå tekniska universitet, Institutionen för teknikvetenskap och matematik, Maskinelement.ORCID-id: 0000-0003-3995-8331
Luleå tekniska universitet, Institutionen för teknikvetenskap och matematik, Maskinelement.ORCID-id: 0000-0003-3157-4632
SKF Engineering and Research Center, Nieuwegein.
Vise andre og tillknytning
2018 (engelsk)Inngår i: Tribology Transactions, ISSN 1040-2004, E-ISSN 1547-397X, Vol. 74, nr 3, s. 60-73Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

The temperature dependence on the dielectric properties of water-contaminated grease is investigated in this article. The purpose of this investigation was to identify the dielectric properties that could be measured to differentiate varying levels of water contamination in calcium sulfonate complex (CaS-X) grease with three different test cells with the purpose of eventually developing a grease condition sensor. Measuring the change in dielectric constant over a small temperature change yielded useful estimations of water content and amount of grease where the added water content ranged from 0.22% to about 5.5%. Additionally, other parameters such as incomplete fill/coverage of the sensors were investigated as a prestudy. The results from this set of experiments show that the measurement has potential to be developed into a condition monitoring sensor in the future.

sted, utgiver, år, opplag, sider
Taylor & Francis, 2018. Vol. 74, nr 3, s. 60-73
HSV kategori
Forskningsprogram
Maskinelement
Identifikatorer
URN: urn:nbn:se:ltu:diva-65054DOI: 10.1080/10402004.2017.1333664ISI: 000444573200001Scopus ID: 2-s2.0-85045005667OAI: oai:DiVA.org:ltu-65054DiVA, id: diva2:1131437
Merknad

Validerad;2018;Nivå 2;2018-04-16 (andbra)

Tilgjengelig fra: 2017-08-14 Laget: 2017-08-14 Sist oppdatert: 2019-09-14bibliografisk kontrollert
Inngår i avhandling
1. Sensors for Water Contamination in Lubricating Grease
Åpne denne publikasjonen i ny fane eller vindu >>Sensors for Water Contamination in Lubricating Grease
2019 (engelsk)Doktoravhandling, med artikler (Annet vitenskapelig)
Abstract [en]

The purpose of this dissertation is to summarize the research carried out that led to the development of measurement techniques which measure the water content of lubricating grease. Calcium sulphonate complex (CaS-X) grease was used in all experiments for Papers A through E, with some additional greases used in Paper D.

A simple and effective grease mixing method for preparing grease samples was developed and tested for repeatability. The water content of these samples was also tested with time and temperature as added variables to study if and how much water will evaporate from the samples.

Additionally, three measurement principles were investigated: optical attenuation in the visible and near-infrared (NIR) region, a dielectric measurement method, and a galvanic current method.

The optical attenuation investigation found that the attenuation ratio of two wavelengths of light appear to approximate the water content of grease samples with an acceptable coefficient of determination. Additionally, aged and oxidized grease samples were measured in the experiment and were not found to affect the measurement results. The dielectric method uses the temperature dependence on the dielectric properties of water-contaminated grease to approximate the water content of the grease samples. An additional parameter of incomplete fill/coverage of the sensor has been investigated as a prestudy. The dielectric method was further optimized with computer automated measurements where an improved and miniaturized sensor was developed and used. A different method using the galvanic current between two different metals from the galvanic series was used to estimate water content as well. All three methods were found to provide measurements of water content in the prepared grease samples (ranging from 0.22% to 5.5% added water). The dielectric measurement is likely going to be better for applications requiring the possibility of measuring a larger bulk of the grease within the bearing, with the capability of using several different configurations of sensors for different types of bearings and applications. It shows promise for providing an accurate and robust system for monitoring grease condition as well as the amount of grease contained. The optical measurement will likely provide additional information; however, it will only measure small point samples within the bearing instead of the larger bulk. This could be of use though, because the sensors could be small (in the several millimeter scale) and could measure where water damage is determined to be most important to detect at. The galvanic current method was also found to provide a useful correlation to water content but may provide additional information about how corrosive the grease has become, indirectly estimating the water content.

The research contained herein has shown promise for future development for developing new grease condition monitoring tools. The optical, dielectric, and galvanic methods have their own unique challenges and may provide useful information in different applications, or perhaps be used in conjunction with each other to provide a more complete diagnostic tool.

sted, utgiver, år, opplag, sider
Luleå University of Technology, 2019. s. 200
Serie
Doctoral thesis / Luleå University of Technology 1 jan 1997 → …, ISSN 1402-1544
HSV kategori
Forskningsprogram
Experimentell mekanik
Identifikatorer
urn:nbn:se:ltu:diva-75998 (URN)978-91-7790-439-7 (ISBN)978-91-7790-440-3 (ISBN)
Disputas
2019-11-04, D770, Luleå, 10:00 (engelsk)
Opponent
Veileder
Tilgjengelig fra: 2019-09-16 Laget: 2019-09-14 Sist oppdatert: 2019-10-16bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstScopus

Personposter BETA

Dittes, NicholasPettersson, AndersMarklund, Pär

Søk i DiVA

Av forfatter/redaktør
Dittes, NicholasPettersson, AndersMarklund, Pär
Av organisasjonen
I samme tidsskrift
Tribology Transactions

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 216 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf