Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
New Power Quality Indices for the Assessment of Waveform Distortions from 0 to 150 kHz in Power Systems with Renewable Generation and Modern Non-Linear Loads
Department of Electrical Engineering and Information Technology, University of Naples Federico II, Italy.
Department of Engineering, University of Naples Parthenope, Centro Direzionale of Naples.
Luleå tekniska universitet, Institutionen för teknikvetenskap och matematik, Energivetenskap.ORCID-id: 0000-0002-9103-0226
2017 (engelsk)Inngår i: Energies, ISSN 1996-1073, E-ISSN 1996-1073, Vol. 10, nr 10, artikkel-id 1633Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

The widespread use of power electronics converters, e.g., to interface renewable generation systems with the grid or to supply some high-efficiency loads, has caused increased levels of waveform distortions in the modern distribution system. Voltage and current waveforms include spectral components from 0 kHz to 150 kHz, characterized by a non-uniform time-frequency behavior. This wide interval of frequencies is currently divided into "low-frequency" (from 0 kHz to 2 kHz) and "high-frequency" (from 2 kHz to 150 kHz). While the low-frequencies have been exhaustively investigated in the relevant literature and are covered by adequate standardization, studies for the high-frequencies have been addressed only in the last decade to fill current regulatory gaps. In this paper, new power quality (PQ) indices for the assessment of waveform distortions from 0 kHz to 150 kHz are proposed. Specifically, some currently available indices have been properly modified in order to extend their application also to wide-spectrum waveforms. In the particular case of waveform distortions due to renewable generation, numerical applications prove that the proposed indices are useful tools for the characterization of problems (e.g., overheating, equipment malfunctioning, losses due to skin effects, hysteresis losses or eddy current losses) in cases of both low-frequency and high-frequency distortions

sted, utgiver, år, opplag, sider
MDPI , 2017. Vol. 10, nr 10, artikkel-id 1633
Emneord [en]
power quality indices, waveform distortions, high-frequency spectral components, fluorescent lamps, renewable generation
HSV kategori
Forskningsprogram
Elkraftteknik
Identifikatorer
URN: urn:nbn:se:ltu:diva-66531DOI: 10.3390/en10101633ISI: 000414578400188Scopus ID: 2-s2.0-85044466671OAI: oai:DiVA.org:ltu-66531DiVA, id: diva2:1155846
Merknad

Validerad;2017;Nivå 2;2017-11-09 (andbra)

Tilgjengelig fra: 2017-11-09 Laget: 2017-11-09 Sist oppdatert: 2019-09-13bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstScopus

Personposter BETA

Larsson, Anders

Søk i DiVA

Av forfatter/redaktør
Larsson, Anders
Av organisasjonen
I samme tidsskrift
Energies

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 153 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf