Evaluating a constant-current load model through comparativetransient stability case studies of a synchronous-synchronous rotary frequencyconverter fed railway
Luleå tekniska universitet, Institutionen för teknikvetenskap och matematik, Energivetenskap.ORCID-id: 0000-0003-2109-060X
Luleå tekniska universitet, Institutionen för teknikvetenskap och matematik, Energivetenskap.
Luleå tekniska universitet, Institutionen för teknikvetenskap och matematik, Energivetenskap.ORCID-id: 0000-0003-4074-9529
2019 (engelsk)Konferansepaper, Publicerat paper (Fagfellevurdert)
Abstract [en]

This paper continues the pursuit of getting a deeperunderstanding regarding the transient stability of lowfrequencyAC railway power systems operated at 162⁄3 Hzsynchronously to the public grid. The focus is set on theimpact of different load models. A simple constant-currentload model is proposed and compared to a previously proposedand studied load model in which the train’s activepower is regulated.The study and comparison is made on exactly the samecases as and grid as with the already proposed and moreadvanced load model. The railway grid is equipped witha low-frequency AC high-voltage transmission line whichis subjected to a fault. The study is limited to railwaysbeing fed by different distributions of RFC (Rotary FrequencyConverter) types. Both AT (auto transformer) andBT (booster transformer) catenaries are considered.The RFC dynamic models are essentially Anderson-Fouad models of two synchronous machines coupled mechanicallyby their rotors being connected to the same shaft.The differences in load behaviour between the proposedconstant-current load model and the previously proposedand studied voltage-dependent active power load model areanalyzed and described in the paper.

sted, utgiver, år, opplag, sider
2019.
HSV kategori
Identifikatorer
URN: urn:nbn:se:ltu:diva-71801OAI: oai:DiVA.org:ltu-71801DiVA, id: diva2:1266648
Konferanse
Proceedings of the 2019 IEEE/ASME Joint Rail Conference
Merknad

Submitted to JRC 2019. Not yet accepted. /20181205

Tilgjengelig fra: 2018-11-28 Laget: 2018-11-28 Sist oppdatert: 2018-12-13
Inngår i avhandling
1. Stability of Low-Frequency AC Railways: Models and Transient Stability
Åpne denne publikasjonen i ny fane eller vindu >>Stability of Low-Frequency AC Railways: Models and Transient Stability
2019 (engelsk)Doktoravhandling, med artikler (Annet vitenskapelig)
Abstract [en]

Low-frequency AC railway grids are unique in the sense that a only few countries around the world uses them, still however, they are an important parts of their countries infrastructures. Due to the usage of a dierent frequency than the public grid of the country, conversion of frequency is needed for the interconnection. The frequency conversion is done by machine based rotary frequency converters or power electronic based static frequency converters.

When reinforcing with new power conversion capacity, mostly static frequency converters are installed since rotary frequency converters for railways have not been manufactured for some time. As more static frequency converterare introduced, the share of rotary frequency converters is reduced. It is not well explored how the stability of low-frequency AC railways is affected with a large share of static frequency converters.

In this thesis, the main goal has been to obtain knowledge of the stability of low-frequency AC railway grids, with focus on synchronous ones. The electromechanical stability of a synchronous low-frequency AC railway is explored through numerical simulations, where the transient stability is the main focus.

The main contributions of this thesis is proposing a model of a rotary frequency converter, proposing a model of a static frequency converter, and transient stability simulations. The model of the rotary frequency converter uses established machine models, whereas the static frequency converter model has been developed with help of measurements. It can be concluded that the proposed static frequency converter model captures the main behaviour of the measurements of a static frequency converter.

The transient stability of synchronous AC railway grids is studied, through numerical simulations. The studied cases are for instance dierent railway grid congurations with dierent types rotary frequency converters and railway grids with mixes of static frequency converters and static frequency converter.

The main conclusion is that the rotary frequency converter fed synchronous railway grids studied are transiently stable, and the studied railway grids where rotary frequency converters are gradually replaced with static frequency converter are also transiently stable. However, it was found that the studied railway grids obtain a heavier oscillatory behaviour when there is a mix of rotary frequency converters and static frequency converters.

sted, utgiver, år, opplag, sider
Luleå: Luleå University of Technology, 2019
Serie
Doctoral thesis / Luleå University of Technology 1 jan 1997 → …, ISSN 1402-1544
HSV kategori
Forskningsprogram
Elkraftteknik
Identifikatorer
urn:nbn:se:ltu:diva-71795 (URN)978-91-7790-292-8 (ISBN)978-91-7790-293-5 (ISBN)
Disputas
2019-02-28, Skellefteå, 10:00 (engelsk)
Opponent
Veileder
Tilgjengelig fra: 2018-12-27 Laget: 2018-12-13 Sist oppdatert: 2019-02-14bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Personposter BETA

Abrahamsson, LarsLaury, JohnBollen, Math

Søk i DiVA

Av forfatter/redaktør
Abrahamsson, LarsLaury, JohnBollen, Math
Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar

urn-nbn

Altmetric

urn-nbn
Totalt: 121 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf