Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Erratum: Techno-economic analysis and performance comparison of aqueous deep eutectic solvent and other physical absorbents for biogas upgrading
Luleå University of Technology, Department of Engineering Sciences and Mathematics, Energy Science. State Key Laboratory of Material-Oriented Chemical Engineering, Nanjing Tech University, Nanjing.ORCID iD: 0000-0002-0453-0450
State Key Laboratory of Material-Oriented Chemical Engineering, Nanjing Tech University, Nanjing.
State Key Laboratory of Material-Oriented Chemical Engineering, Nanjing Tech University, Nanjing.
Luleå University of Technology, Department of Engineering Sciences and Mathematics, Energy Science.ORCID iD: 0000-0002-0200-9960
2019 (English)In: Applied Energy, ISSN 0306-2619, E-ISSN 1872-9118, Vol. 235, p. 1669-1670Article in journal, Letter (Refereed) Published
Abstract [en]

The authors regret to inform that there are errors in the vertical axis of Figs. 4 and 5 as well as corresponding text. The corrected versions are given below. (Figure presented.) Fig. 4b: the left y-axis should read “$·Nm-3 CH4” instead of “k$·Nm-3 CH4”; The corrected version of Fig. 5 is shown below. Abstract: The text at the end of Abstract: ‘For the case with …respectively’ should read: “…with AQ50wt.%DESand PC decrease by…” instead of “…with PC and AQ50wt.%DES decrease by…” Section 3.3.2: The text at the end of paragraph 5: ‘The results of specific TAC of using…than that using water, respectively. ’ should read: “…using AQ50wt.%DES and PC decrease by ….” instead of “…using PC and AQDES decrease by…” “…using AQ50wt.%DES and PC increase up to…” instead of “…using PC and AQ50wt.%DESincrease up to…” The text at the end of paragraph 6: ‘While, using…raw biogas capacity. ’ should read: “…and 25% than water…” instead of “…and 50% than water…” Conclusion: The text at the end of paragraph 2: ‘The results of specific TAC of using PC …than PC should be developed.’ should read: “…using AQ50wt.%DES and PC decrease by…” instead of “…using PC and AQ50wt.%DES decrease by…” “…using AQ50wt.%DES and PC treated with…” instead of “…using PC and AQ50wt.%DES treated with…” The above errors do not reflect any calculations errors and do not compromise the findings of the paper. The authors would like to apologize for any inconvenience caused. 

Place, publisher, year, edition, pages
Elsevier, 2019. Vol. 235, p. 1669-1670
National Category
Energy Engineering
Research subject
Energy Engineering
Identifiers
URN: urn:nbn:se:ltu:diva-72798DOI: 10.1016/j.apenergy.2018.09.218ISI: 000458942800133Scopus ID: 2-s2.0-85060587157OAI: oai:DiVA.org:ltu-72798DiVA, id: diva2:1286098
Note

Erratum in: Energy, Vol. 225, s. 437-447, DOI: 10.1016/j.apenergy.2018.04.112

Available from: 2019-02-06 Created: 2019-02-06 Last updated: 2019-03-27Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textScopus

Authority records BETA

Ma, ChunyanJi, Xiaoyan

Search in DiVA

By author/editor
Ma, ChunyanJi, Xiaoyan
By organisation
Energy Science
In the same journal
Applied Energy
Energy Engineering

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 39 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf