Energisimuleringar av trapphus
Luleå University of Technology, Department of Civil, Environmental and Natural Resources Engineering. Lindbäcks Bygg AB. (Industriellt och hållbart byggande)
2019 (Swedish)Independent thesis Advanced level (professional degree), 20 credits / 30 HE creditsStudent thesisAlternative title
Energisimuleringar av trapphus (Swedish)
Abstract [sv]

Ett varmt trapphus tyder på att det sker oavsiktligt värmeläckage någonstans i byggnaden. Det är av vikt att ta reda på orsaken till värmeläckaget för att kunna minska energiförluster. I Lindbäcks flervåningshus finns trapphus som är för varma än vad de är tänkt att vara. I den här studien undersöks en av byggnaderna med ett varmt trapphus som jämförs med en byggnad med ett trapphus i normal temperatur. Studien har genomförts i simuleringsverktyget IDA ICE. Data har samlats in för byggnadernas utformning, materialinnehåll och installationer. Byggnaderna har modellerats upp i simuleringsverktyget och tillförts brukarbeteenden enligt de rekommendationer som finns för energiberäkningar. Olika parametrar har studerats och analyserats i simuleringsmiljön utifrån byggnadernas befintliga utförande.

Resultaten från simuleringarna visar vad de boende i byggnaderna upplever. Byggnaden med ett varmt trapphus visar upp emot 30 grader året runt i simuleringsmodellen av befintligt utförande. Parameterstudien visar att det finns åtgärder som kan påverka det termiska klimatet i positiv riktning. Simuleringar visar att värmeförluster från dåligt isolerade varmvattenledningar är en betydande orsak till temperaturökningarna i trapphusen. Genom att isolera varmvattenledningarna kan medeltemperaturen för alla våningsplan sjunka med 2,7 grader i ett snitt över hela året. Det kan däremot vara problematiskt att isolera vissa ledningar i byggsystemet eftersom de är svåra att komma åt. Genom att använda böjbar rörisolering skulle förbättringar i den termiska komforten kunna upplevas.

Abstract [en]

A warm stairwell indicates that accidental heat leakage occurs somewhere in the building. It is important to find out the cause of the heat leakage in order to reduce energy losses. In Lindbäck's multi-storey houses there are stairwells that are too hot than they are supposed to be. In this study, one of the buildings with a warm stairwell is analysed and is compared with a building with a stairwell in normal indoor temperature. The study has been carried out in the simulation tool IDA ICE. Data has been collected for the design of the buildings, material content and installations. The buildings have been modelled in the simulation tool and added user behaviours according to the recommendations for energy calculations. Various parameters have been studied and analysed in the simulation environment based on the existing construction of the buildings.

The results from the simulations show what the residents in the buildings are experiencing. The building with a warm stairwell indicates up to 30 degrees all year round in the simulation model of the existing design. The parameter study shows that there are measures that can affect the thermal climate in a positive direction. Simulations show that heat losses from poorly insulated hot water pipes are a major cause of the hot temperatures in the stairwells. By isolating the hot water pipes, the average temperature for all floors can fall by 2.7 degrees in an average throughout the year. However, it may be problematic to isolate certain pipes in the building system because they are difficult to access. By using flexible pipe insulation, improvements in the thermal comfort could be experienced.

Place, publisher, year, edition, pages
2019. , p. 102
Keywords [sv]
Energieffektivisering, inomhustemperatur, värmeläckage, installationer, simulering, IDA ICE, parameterstudie
National Category
Building Technologies
Identifiers
URN: urn:nbn:se:ltu:diva-72627OAI: oai:DiVA.org:ltu-72627DiVA, id: diva2:1290144
External cooperation
Lindbäcks Bygg AB
Subject / course
Student thesis, at least 30 credits
Educational program
Architectural Engineering, master's level
Supervisors
Examiners
Available from: 2019-03-06 Created: 2019-02-19 Last updated: 2019-03-06Bibliographically approved

Open Access in DiVA

fulltext(6391 kB)30 downloads
File information
File name FULLTEXT01.pdfFile size 6391 kBChecksum SHA-512
643f23e12d3735384acdf78be5ed66990b6030a7e7e79fb52005bd863e66a439f836d71ead87e6d3afa2b6de18834dc151177617602328bf14283461a2bde86c
Type fulltextMimetype application/pdf

By organisation
Department of Civil, Environmental and Natural Resources Engineering
Building Technologies

Search outside of DiVA

GoogleGoogle Scholar
Total: 30 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 42 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf