Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
A sensitive enzyme-free lactic acid sensor based on NiO nanoparticles for practical applications
Luleå tekniska universitet, Institutionen för teknikvetenskap och matematik, Materialvetenskap. National Centre of Excellence in Analytical Chemistry, University of Sindh, Jamshoro, Pakistan. Department of Chemistry, Shaheed Benazir Bhutto University, Shaheed Benazirabad, Pakistan.
Luleå tekniska universitet, Institutionen för teknikvetenskap och matematik, Materialvetenskap.ORCID-id: 0000-0001-6777-5642
National Centre of Excellence in Analytical Chemistry, University of Sindh, Jamshoro, Pakistan.
Luleå tekniska universitet, Institutionen för teknikvetenskap och matematik, Materialvetenskap.ORCID-id: 0000-0003-4598-9556
Visa övriga samt affilieringar
2019 (Engelska)Ingår i: Analytical Methods, ISSN 1759-9660, E-ISSN 1759-9679, Vol. 11, s. 3578-3583Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

A facile and efficient electrochemical sensing platform has been successfully exploited for the first time for the determination of lactic acid using a nickel oxide (NiO) nanoparticle-modified glassy carbon electrode (GCE). Nickel oxide nanoparticles were prepared by a chemical growth method using different quantities of arginine as a soft template. The structural and morphological properties of NiO nanoparticles were characterized by Raman spectroscopy, scanning electron microscopy (SEM) and X-ray diffraction (XRD). Cyclic voltammetry (CV) was used to study the electrochemical properties of various samples. The modified electrode is highly sensitive and presents a linear response over a wide range (0.005–5 mM) of lactic acid concentrations in 0.1 M NaOH. The detection limit for the sensor was found to be 5.7 μM, and it exhibits good stability. Furthermore, the sensor shows excellent selectivity in the presence of common interfering species. The lactic acid sensor showed good viability for lactic acid analysis in real samples (milk, yogurt and red wine) and demonstrated significant advancement in sensor technology for practical applications.

Ort, förlag, år, upplaga, sidor
Royal Society of Chemistry, 2019. Vol. 11, s. 3578-3583
Nationell ämneskategori
Annan fysik
Forskningsämne
Experimentell fysik
Identifikatorer
URN: urn:nbn:se:ltu:diva-75559DOI: 10.1039/C9AY00516AISI: 000475986600010Scopus ID: 2-s2.0-85069500109OAI: oai:DiVA.org:ltu-75559DiVA, id: diva2:1343432
Anmärkning

Validerad;2019;Nivå 2;2019-08-16 (johcin)

Tillgänglig från: 2019-08-16 Skapad: 2019-08-16 Senast uppdaterad: 2022-10-27Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextScopus

Person

Tahira, AneelaMazzaro, RaffaelloIbupoto, ZafarVomiero, Alberto

Sök vidare i DiVA

Av författaren/redaktören
Tahira, AneelaMazzaro, RaffaelloIbupoto, ZafarVomiero, Alberto
Av organisationen
Materialvetenskap
I samma tidskrift
Analytical Methods
Annan fysik

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 90 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf