Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
The Lysholm score: Cross cultural validation and evaluation of psychometric properties of the Spanish version
Department of Physical Therapy, University of Granada, Granada, Spain. Biohealth Research Institute in Granada (ibs.GRANADA), Granada, Spain, Sport and Health University Research Institute (iMUDS), Granada, Spain.
Orthopedic Surgery Service Hospital Nuestra Señora de la Salud, Granada, Spain.
Department of Physical Therapy, University of Granada, Granada, Spain. Sport and Health University Research Institute (iMUDS), Granada, Spain.
Department of Physical Therapy, Faculty of Health Sciencies, University of Málaga, Andalucia. Instituto de Investigación en Biomedica de Málaga (IBIMA), Grupo de Clinimetria, Malaga, Spain. School of Clinical Sciences, The Queensland University of Technology, Brisbane, Australia.
Vise andre og tillknytning
2019 (engelsk)Inngår i: PLoS ONE, ISSN 1932-6203, E-ISSN 1932-6203, Vol. 14, nr 8, artikkel-id e0221376Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Background

This study aims at assessing the validity and reliability of the Spanish version of the Lysholm score, a widely used instrument for assessing knee function and activity level after ligament injuries.

Methods

Ninety-five participants (67.4% male, 22±5 years) completed the questionnaire twice within 7 days and a subsample of 42 participants completed a test-retest reliability. Reliability, validity and feasibility psychometric properties were studied. The validity of the questionnaire was analysed using ceiling and floor effects. Factor structure and construct validity were analysed with the SF-36, the Hip and Knee Questionnaire (HKQ) and one leg jump test (OLJT).

Results

Criterion validity with the SF-36 Physical State was moderate (r = 0.50 and p<0.01), poor and inverse relationship (r = -0.31, p<0.01) with HKQ and positive moderate (r = 0.59, p<0.01) with OLJT. Measurement error from MDC90 was 3.9%. Exploratory factor analysis demonstrated a one-factor solution explaining 51.5% of total variance. The x2 test for the one-factor model was significant (x2 = 29.58, df = 20, p < 0.08). Test-retest reliability level was high (ICC2.1 = 0.92, p<0.01) and also the internal consistency (α = 0.77).

Conclusion

The Spanish Lysholm score demonstrated that it is a reliable and valid instrument that can be used to assess knee function after ligament injuries.

sted, utgiver, år, opplag, sider
Public Library of Science , 2019. Vol. 14, nr 8, artikkel-id e0221376
HSV kategori
Forskningsprogram
Hälsovetenskap
Identifikatorer
URN: urn:nbn:se:ltu:diva-75857DOI: 10.1371/journal.pone.0221376ISI: 000485049000018PubMedID: 31454386OAI: oai:DiVA.org:ltu-75857DiVA, id: diva2:1348833
Merknad

Validerad;2019;Nivå 2;2019-09-05 (johcin)

Tilgjengelig fra: 2019-09-05 Laget: 2019-09-05 Sist oppdatert: 2019-10-08bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstPubMed

Personposter BETA

Tegner, Yelverton

Søk i DiVA

Av forfatter/redaktør
Tegner, Yelverton
Av organisasjonen
I samme tidsskrift
PLoS ONE

Søk utenfor DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric

doi
pubmed
urn-nbn
Totalt: 20 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf