Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Estimation of Faecal Indicator Bacteria in Stormwater by Multiple Regression Modelling and Microbial Partitioning to Solids
Luleå tekniska universitet, Institutionen för samhällsbyggnad och naturresurser, Arkitektur och vatten.
Luleå tekniska universitet, Institutionen för samhällsbyggnad och naturresurser, Arkitektur och vatten.ORCID-id: 0000-0002-4732-7348
Luleå tekniska universitet, Institutionen för samhällsbyggnad och naturresurser, Arkitektur och vatten.ORCID-id: 0000-0001-9938-8217
Luleå tekniska universitet, Institutionen för samhällsbyggnad och naturresurser, Arkitektur och vatten.ORCID-id: 0000-0003-1725-6478
2019 (Engelska)Ingår i: New Trends in Urban Drainage Modelling: New Trends in Urban Drainage Modelling, 2019, s. 830-835Konferensbidrag, Publicerat paper (Refereegranskat)
Abstract [en]

Concerns about the contamination of sources of drinking water by stormwater motivated a sanitary survey of several urban catchments in the City of Östersund (Northern Sweden). A data subset from these surveys, comprising of faecal indicator bacteria (FIB) concentrations (E. coli and enterococci), measured for six storm events in three catchments, was used for investigating the feasibility of developing a FIB estimation procedure for the studied catchments by two approaches: (a) Multiple regression models, and (b) microbial partitioning to solids. In regressions, five explanatory variables (associated constituents) were derived from the literature and measured data: stormwater temperature and flow rate, and measurements of total suspended solids (TSS), total phosphorus (TP) and electric conductivity (EC). The obtained regression models were satisfactory for enterococci (regression of modelled FIBs on measured FIB was described by R2 = 0.7), but less acceptable for E. coli (R2 = 0.2). Microbial partitioning to stormwater solids from gully pots was found infeasible; the sediment sampled contained very low FIB counts. Hence, the former method is recommended for further refinement and applications.

Ort, förlag, år, upplaga, sidor
2019. s. 830-835
Serie
Green Energy and Technology, ISSN 1865-3529, E-ISSN 1865-3537
Nyckelord [en]
Faecal indicator bacteria (FIBs), Sanitary surveys of storm sewers, Statistical modelling of FIBs
Nationell ämneskategori
Vattenteknik
Forskningsämne
VA-teknik; Centrumbildning - Centrum för dagvattenhantering (DRIZZLE)
Identifikatorer
URN: urn:nbn:se:ltu:diva-77754DOI: 10.1007/978-3-319-99867-1_143ISI: 000482068800143Scopus ID: 2-s2.0-85071528255OAI: oai:DiVA.org:ltu-77754DiVA, id: diva2:1394128
Konferens
11th International Conference on Urban Drainage Modelling (UDM), 23-26 September, 2018, Palermo, Italy
Anmärkning

ISBN för värdpublikation: 978-3-319-99866-4, 978-3-319-99867-1

Tillgänglig från: 2020-02-18 Skapad: 2020-02-18 Senast uppdaterad: 2023-09-05Bibliografiskt granskad
Ingår i avhandling
1. Assessment of stormwater and snowmelt quality based on water management priorities and the consequent water quality parameters
Öppna denna publikation i ny flik eller fönster >>Assessment of stormwater and snowmelt quality based on water management priorities and the consequent water quality parameters
2020 (Engelska)Doktorsavhandling, sammanläggning (Övrigt vetenskapligt)
Abstract [en]

Stormwater and snowmelt pollution contributes to degradation of quality of the receiving waters. For assessing such impacts, it is effective to focus on specific causes of degradation, as done in this study of the quality of stormwater and snowmelt discharges into the receiving waters serving for supply of raw drinking water and water-based recreation. While the main priority were faecal indicator bacteria (FIBs), the understanding of their occurrence, and of other potential effects on the receiving waters, required addressing additional water quality parameters as well.     

Exports of FIBs in stormwater and snowmelt discharged from four urban catchments yielded the following findings: (a) E.coli, with mean concentration of all stormwater data Cmean = 430 cfu (colony forming units)/100 mL, and enterococci (Cmean=1380 cfu/100 mL) were the best indicators of faecal pollution of stormwater, but total coliform (Cmean=3130 cfu/100 mL) and C. perfringens (Cmean=150 cfu/100 mL) were much less effective: the former indicator includes non-faecal bacteria and the latter one barely varied; (b) Among the different catchments, the central catchment with mixed land use produced the highest concentrations of FIBs; (c) FIB concentrations in snowmelt were significant only in the case of enterococci (400 cfu/100 mL); and, (d) Baseflows in two catchments were practically devoid of FIBs, with Cmean=10 cfu/100 mL for both E.coli and enterococci. Hence, there were no contributions of sanitary sewage to the storm sewer baseflows.

FIB concentrations varied with stormwater or snowmelt quality, described by associated parameters, which were identified by cluster analysis as: temperature, conductivity, TSS, flow rate, and TP. Such findings were used in statistical regressions indicating that E. coli and enterococci could be statistically modelled in three of the four catchments, with determination coefficients R2 ranging from 38-66%. In spite of uncertainties, such modelling would be useful for future FIB monitoring, or for comparing remediation alternatives. Estimation of FIBs by microbial partitioning to settleable solids (represented by gully pot sediments) was infeasible, because these highly mineral sediments contained little FIBs.

Storm sewer outfall effluents were also analyzed for mineral (Al, Ca, Fe, K, Mg, Na) and anthropogenic indicator trace metal (TM) inorganics (Cd, Cr, Cu, Ni, Pb, Zn). The total mass of inorganics exported from the catchments by runoff or snowmelt was dominated by mineral inorganics, which were particularly high in baseflows. TM concentrations were compared to the tentative guidance limits suggested in Sweden as annual mean, or maximum event mean, total TM concentrations. Effluents from the catchments studied clearly exceeded the recommended values 5 times in the case of Zn.

Field studies drew attention to uncertainties in measured FIBs and solids. Automated sampling of greatly varying FIB concentrations was affected by sampling line water residuals, which can be minimized by short sampling lines and avoidance of sags in the sampling line. Stormwater and snowmelt solids were underestimated by the conventional TSS method requiring withdrawal of aliquots from total samples. This bias can be eliminated by using whole-sample methods; either the existing SSC (suspended sediment concentration) method, or the newly proposed (and easier to use) multiple filter procedure (MFP), filtering whole samples through progressively finer filters (pore sizes 25, 1.6 and 0.45 µm). The MFP produced data equivalent to those obtained with SSC, as confirmed by the Limits of Agreement (LoA) statistical procedure.

Abstract [sv]

Dagvatten från regn och snösmältning är viktiga komponenter i föroreningstransport till ytvattentäkter som används för dricksvattenproduktion och badvatten. I denna studie har potentiella källor och transportvägar av mikrobiologiska föroreningar studerats i Östersund genom mätningar och utvärdering av fekala indikatorbakterier (FIB) i dagvatten som släpps ut i den närliggande Storsjön. Även andra föroreningar, så som metaller, ingick i studien för att bättre förstå källorna till och förhållanden mellan dessa parametrar och FIB.

Transport av FIB i dagvatten som släppts ut från fyra urbana avrinningsområden gav följande resultat: (a) E. koli, med medelkoncentration av all data sammanlagt (Cmean = 430 cfu (kolonibildande enheter)/100 ml), och enterokocker (Cmean = 1380 cfu/100 ml), var de bästa fekala indikatorerna; (b) koliformer (Cmean = 3130 cfu/100 ml) och C. perfringens (Cmean = 150 cfu/100 ml) var mycket mindre effektiv som indikator; där koliformer inkluderar icke-fekala bakterier och C. perfringens uppvisade knappt någon variation mellan platser och provtagningstillfällen; (c) mellan de olika avrinningsområdena uppmättes de högsta halterna av FIB i ett centralt avrinningsområde med blandad markanvändning; (d) FIB-halter i snösmältning var endast signifikanta för enterokocker (400 = cfu/100 ml) och (e) i basflöden, vilket förekom i två av avrinningsområdena, uppmättes nästan inga FIB. Följaktligen har dagvattnet i dessa områden inte påverkats av felkopplingar eller inläckage av spillvatten.

FIB-halter varierade i dagvatten från regn och snösmältning beroende av andra parametrar. Hur dessa parametrar relaterade till FIB identifierades genom klusteranalys. Parametrarna var: temperatur, konduktivitet, suspenderade ämnen (TSS), flödeshastighet och fosfor. Dessa har vidare använts i regressionsanalys. E. koli och enterokocker kunde statistiskt modelleras i tre avrinningsområden med determinationskoefficienter, R2, mellan 38-66%. Trots osäkerheter skulle sådan modellering vara användbar för framtida FIB-övervakning eller för att jämföra olika alternativ av åtgärder. Uppskattning av FIB genom provtagning av dagvattensediment i rännstensbrunnar lyckades inte, eftersom dessa mycket mineralhaltiga partiklar innehöll låga FIB-halter.

Dagvatten analyserades även för oorganiska ämnen såsom mineraler (Al, Ca, Fe, K, Mg, Na) och antropogena tungmetaller (Cd, Cr, Cu, Ni, Pb, Zn). Transport av oorganiska ämnen från avrinningsområden via dagvattenledningar dominerades av mineraler som uppvisade höga halter i basflöden. Tungmetallhalter jämfördes med riktvärden som föreslagits i Sverige. Dagvatten i respektive avrinningsområde överskred de rekommenderade värdena fem gånger för Zn.

Vid genomförda fältstudier påvisades osäkerheter i uppmätta FIB-halter och suspenderade ämnen. Automatiserad provtagning med kraftigt varierande FIB-halter påverkades av rester av vattnet i provtagningsslangarna, vilket kan minimeras genom kortare provtagningsslang utan böjar i provtagningslinjen. Vidare påvisades att mängden suspenderade ämnen i dagvatten underskattades med den konventionella TSS-metoden som innebär analys på delprov istället av helprov. Felkällor i uppskattning kan elimineras med hjälp av helprovsanalys; antingen den befintliga SSC-metoden (suspenderad sedimentkoncentration) eller i denna studie föreslagen MFP (multipel filter procedure) som innebär filtrering av hela provet genom succesivt finare filter (porstorlekar 25, 1,6 och 0,45 µm). MFP genererade resultat som var ekvivalenta med de som erhölls med SSC, vilket bekräftas genom statistiska metoder.

Ort, förlag, år, upplaga, sidor
Luleå University of Technology, 2020. s. 85
Serie
Doctoral thesis / Luleå University of Technology 1 jan 1997 → …, ISSN 1402-1544
Nyckelord
Stormwater quality, indicator bacteria, water quality assessment
Nationell ämneskategori
Vattenteknik
Forskningsämne
VA-teknik; Centrumbildning - Centrum för dagvattenhantering (DRIZZLE)
Identifikatorer
urn:nbn:se:ltu:diva-77915 (URN)978-91-7790-546-2 (ISBN)978-91-7790-547-9 (ISBN)
Disputation
2020-05-05, A117, 14:00 (Engelska)
Opponent
Handledare
Tillgänglig från: 2020-03-02 Skapad: 2020-03-01 Senast uppdaterad: 2023-09-05Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextScopus

Person

Galfi, HelenÖsterlund, HeleneMarsalek, JiriViklander, Maria

Sök vidare i DiVA

Av författaren/redaktören
Galfi, HelenÖsterlund, HeleneMarsalek, JiriViklander, Maria
Av organisationen
Arkitektur och vatten
Vattenteknik

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 72 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf