Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Comparison of Goldmann applanation and applanation resonance tonometry in a biomicroscope-based in vitro porcine eye model
Umeå University Hospital, Department of Biomedical Engineering & Informatics.
Umeå University, Department of Clinical Science, Ophthalmology.
Umeå University, Centre for Biomedical Engineering and Physics.
Visa övriga samt affilieringar
2006 (Engelska)Ingår i: Journal of Medical Engineering & Technology, ISSN 0309-1902, E-ISSN 1464-522X, Vol. 30, nr 6, s. 345-52Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

We have developed an in vitro porcine eye model based on a biomicroscope, to simulate a clinical situation for IOP measurement on enucleated eyes. The aims of this study were to evaluate the model and to apply and compare Goldmann applanation tonometry (GAT) and applanation resonance tonometry (ART) measurements in porcine eyes. The GAT measurement (IOPGAT) showed a lower pressure, mean - 14.0 mm Hg (SD = 1.7 mm Hg) as compared with the reference pressure. For in vitro measurement with GAT on porcine eyes the linear calibration was IOP = 1.14 IOPGAT + 12.5 mm Hg (R2 = 0.99, p < 0.001, n = 280, four eyes). ART measurements correlated significantly to reference IOP, R = 0.86 (p < 0.001, n = 252, six eyes), with a mean difference of 5.4 mm Hg (SD = 6.7 mm Hg). GAT could only be used on porcine eyes if the IOP exceeded 13 mm Hg. Evaluation of the ART in this in vitro model showed position dependence for the sensor. To facilitate centre positioning a guiding tool is suggested. Porcine eyes are a possible substitute for human eyes in in vitro models for pre-clinical evaluation of new tonometry methods.

Ort, förlag, år, upplaga, sidor
2006. Vol. 30, nr 6, s. 345-52
Nationell ämneskategori
Annan medicinteknik
Forskningsämne
Medicinsk teknik för hälsovård
Identifikatorer
URN: urn:nbn:se:ltu:diva-6295DOI: 10.1080/03091900512331332528Lokalt ID: 4818ee30-0f61-11dc-b9dd-000ea68e967bOAI: oai:DiVA.org:ltu-6295DiVA, id: diva2:979172
Anmärkning
Upprättat; 2006; 20070531 (andbra)Tillgänglig från: 2016-09-29 Skapad: 2016-09-29 Senast uppdaterad: 2017-11-24Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltext

Personposter BETA

Lindahl, Olof

Sök vidare i DiVA

Av författaren/redaktören
Lindahl, Olof
I samma tidskrift
Journal of Medical Engineering & Technology
Annan medicinteknik

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 89 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf