Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Study on harmonic emission of domestic equipment combined with different types of lighting
Universidad de Córdoba, Area de Electrónica, Dpto. Arquitectura de Computadores, Electrónica y Tecnología Electrónica, Escuela Politécnica Superior, Campus de Rabanales.
Luleå tekniska universitet, Institutionen för teknikvetenskap och matematik, Energivetenskap.ORCID-id: 0000-0002-4004-0352
Luleå tekniska universitet, Institutionen för teknikvetenskap och matematik, Energivetenskap.ORCID-id: 0000-0003-4074-9529
Universidad de Córdoba, Area de Electrónica, Dpto. Arquitectura de Computadores, Electrónica y Tecnología Electrónica, Escuela Politécnica Superior, Campus de Rabanales.
2014 (engelsk)Inngår i: International Journal of Electrical Power & Energy Systems, ISSN 0142-0615, E-ISSN 1879-3517, Vol. 55, s. 116-127Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

This paper presents the results of a set of measurements to study changes in harmonic emission from domestic equipment due to the introduction of energy-efficient lamps. During this study measurements have been performed of the emission from different combinations of domestic devices in combination with different kind of lamps. Those results are then compared with standards, with a mathematical aggregation model and with results from field experiments in order to give recommendations to different stakeholders. The measurements clearly show that the total emission depends on the lamps that are connected as a background. It is however not possible to draw the general conclusion that the introduction of CFLs and LED lamps will result in an increase or decrease of emission. It is also concluded in this work that the IEC aggregation model does not give useful estimations of changes in emission from domestic installations due to the introduction of CFLs and LED lamps. The measurement results further indicate that emission levels at higher frequencies might increase due to the large-scale introduction of such lamps.

sted, utgiver, år, opplag, sider
2014. Vol. 55, s. 116-127
HSV kategori
Forskningsprogram
Elkraftteknik
Identifikatorer
URN: urn:nbn:se:ltu:diva-8804DOI: 10.1016/j.ijepes.2013.09.001ISI: 000329333100014Scopus ID: 2-s2.0-84885104763Lokal ID: 759fb315-fa65-42ca-8f96-bb6251d12b7aOAI: oai:DiVA.org:ltu-8804DiVA, id: diva2:981742
Merknad
Validerad; 2013; 20130930 (andbra)Tilgjengelig fra: 2016-09-29 Laget: 2016-09-29 Sist oppdatert: 2018-07-10bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstScopus

Personposter BETA

Rönnberg, SarahBollen, Math

Søk i DiVA

Av forfatter/redaktør
Rönnberg, SarahBollen, Math
Av organisasjonen
I samme tidsskrift
International Journal of Electrical Power & Energy Systems

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 24 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf