An applanation resonator sensor for measuring intraocular pressure using combined continuous force and area measurement
Umeå University Hospital, Department of Biomedical Engineering & Informatics.
Umeå University Hospital, Department of Biomedical Engineering & Informatics.
Umeå University, Center for Biomedical Engineering and Physics.
2003 (English)In: Investigative Ophthalmology and Visual Science, ISSN 0146-0404, E-ISSN 1552-5783, Vol. 44, no 7, p. 3017-24Article in journal (Refereed) Published
Abstract [en]

PURPOSE: For diagnostic purposes and for follow-up after treatment, it is important to have simple and reliable methods for measuring intraocular pressure (IOP). The purpose of this study was to develop a new applanation method for IOP measurement that uses combined continuous force and area measurement and to develop and evaluate an applanation resonator sensor (ARS) tonometer based on that method. METHODS: The tonometer was developed and evaluated in an in vitro porcine eye model, in which enucleated eyes were pressurized with a saline column. A model assuming that the applanation principle is valid over a certain interval of contact area was proposed. Continuous contact area was measured with a resonator sensor device, and contact force was measured with a force transducer, both mounted together in one probe. Reference IOP was measured in the vitreous chamber (IOP(VC)) with a standard fluid pressure transducer. RESULTS: An optimization algorithm determined the applanation interval that was optimal for calculating IOP(ARS). The corresponding time interval was 30 +/- 3 to 77 +/- 4 ms (mean +/- SD, n = 418) after initial contact. The proposed model showed a degree of explanation of R(2 [supi]) = 0.991 (n = 410, six eyes), corresponding to a correlation of r = 0.995 (n = 410) between IOP(ARS) and IOP(VC). The within-eyes precision (i.e., 95% confidence interval for the residuals between IOP(ARS) and IOP(VC)) was +/- 1.8 mm Hg (n = 410, six eyes). CONCLUSIONS: In this study, the ARS method for measuring IOP was evaluated in an in vitro porcine eye model and showed high precision. The ARS method is, to the authors' knowledge, the first to combine simultaneous, continuous sampling of both parameters included in the applanation principle: force and area. Consequently, there is a potential for reducing errors in clinical IOP tonometry.

Place, publisher, year, edition, pages
2003. Vol. 44, no 7, p. 3017-24
National Category
Other Medical Engineering
Research subject
Medical Engineering for Healthcare
Identifiers
URN: urn:nbn:se:ltu:diva-13099DOI: 10.1167/iovs.02-1116Local ID: c4397c80-0f59-11dc-b9dd-000ea68e967bOAI: oai:DiVA.org:ltu-13099DiVA, id: diva2:986050
Note
Upprättat; 2003; 20070531 (andbra)Available from: 2016-09-29 Created: 2016-09-29 Last updated: 2017-11-24Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full text

Authority records BETA

Lindahl, Olof

Search in DiVA

By author/editor
Lindahl, Olof
In the same journal
Investigative Ophthalmology and Visual Science
Other Medical Engineering

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 47 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf