Robustness properties of repetitive controllers
Luleå tekniska universitet, Institutionen för system- och rymdteknik, Signaler och system.
1996 (Engelska)Ingår i: International Journal of Control, ISSN 0020-7179, E-ISSN 1366-5820, Vol. 65, nr 6, s. 939-961Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Stability robustness properties of sampled data repetitive control systems are examined. Due to the infinite loop gain at periodic frequencies originating from the included internal model (Internal Model Principle), repetitive systems are, if properly designed, not very sensitive towards possibly time-varying gains. Uncertainty in plant delay is, however, a problem. Controller action timing becomes more or less out of order and may result in severe performance degradation, depending on model type and the number of frequencies included in the design. With a Linear Time-Invariant (LTI) controller comprising the commonly used time delay internal model, the closed loop system is stable for nominal time delay plus/minus at most one sampling interval. A controller based on a reduced order model, perhaps not modelling all harmonics, is utilized to enhance robustness properties. Simulation runs with different controllers show how different models work in the closed loop, and also that synchronization in time is of utmost importance in order to utilize the delay internal model.Stability robustness properties of sampled data repetitive control systems are examined. Due to the infinite loop gain at periodic frequencies originating from the included internal model (Internal Model Principle), repetitive systems are, if properly designed, not very sensitive towards possibly time-varying gains. Uncertainty in plant delay is, however, a problem. Controller action timing becomes more or less out of order and may result in severe performance degradation, depending on model type and the number of frequencies included in the design. With a Linear Time-Invariant (LTI) controller comprising the commonly used time delay internal model, the closed loop system is stable for nominal time delay plus/minus at most one sampling interval. A controller based on a reduced order model, perhaps not modelling all harmonics, is utilized to enhance robustness properties. Simulation runs with different controllers show how different models work in the closed loop, and also that synchronization in time is of utmost importance in order to utilize the delay internal model.

Ort, förlag, år, upplaga, sidor
1996. Vol. 65, nr 6, s. 939-961
Nationell ämneskategori
Reglerteknik
Forskningsämne
Reglerteknik
Identifikatorer
URN: urn:nbn:se:ltu:diva-14313Lokalt ID: da9b34e0-bf82-11db-834c-000ea68e967bOAI: oai:DiVA.org:ltu-14313DiVA, id: diva2:987268
Anmärkning

Godkänd; 1996; 20070218 (ysko)

Tillgänglig från: 2016-09-29 Skapad: 2016-09-29 Senast uppdaterad: 2018-02-06Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Sök vidare i DiVA

Av författaren/redaktören
Hillerström, Gunnar
Av organisationen
Signaler och system
I samma tidskrift
International Journal of Control
Reglerteknik

Sök vidare utanför DiVA

GoogleGoogle Scholar

urn-nbn

Altmetricpoäng

urn-nbn
Totalt: 27 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf