High frequency distortion in power grids due to electronic equipment
Luleå tekniska universitet, Institutionen för teknikvetenskap och matematik, Energivetenskap.ORCID-id: 0000-0002-9103-0226
2006 (Engelska)Licentiatavhandling, sammanläggning (Övrigt vetenskapligt)
Abstract [en]

Power quality is a subject that has received a lot of attention during the last 10 to 20 years, both in industry and in academia. Power quality concerns interaction between the power grid and its customers and between the power grid and equipment connected to it, reflected in voltages and currents. Research and other developments in this area have to a great extent concentrated on relatively slow and low-frequency phenomena, with the main emphasis being on voltage dips (reductions in voltage magnitude with duration between about 50 ms and several seconds) and low-frequency harmonics (waveform distortion by frequency components up to about 2 kHz). These phenomena are reasonably well understood. For higher-frequency phenomena there is no such general understanding. There are a number of reasons for looking closer into this frequency range, including increased distortion by energy-efficient equipment, interference with equipment such as that used for communications, reduced service life of equipment, the availability of measurement and analysis tools, and pure scientific curiosity. This licentiate thesis addresses voltage and current distortion in low- voltage networks in the frequency range between 2 kHz and 1 MHz. The report starts with a general overview of power quality and power-quality disturbances. This part is mainly a review of existing knowledge. The report continues with a philosophical discussion of measurement and analysis of power-quality disturbances. The objectiveness of the analysis methods is especially addressed. The importance of understanding the limitations posed by measurement standards and commonly used analysis methods is emphasized. The choice of measurement and analysis tool has the potential to influence the conclusions drawn from a study. Different analysis and presentation tools are discussed for disturbances in the frequency band of interest. Where possible, a range of methods should be used. Next to the commonly used time- and frequency-domain presentations, the spectrogram or time-frequency-domain is introduced as a useful tool. The measurement technology used for obtaining sampled voltage and current waveforms is discussed. Measurements have been performed on the current drawn by individual devices and by groups of devices. These measurements have been performed mainly in a controlled laboratory environment. Voltage measurements have mainly been performed at a number of locations in the field. Both current and voltage measurements are described in detail in this report, together with the measurement results. The main contribution of this licentiate report is in the systematic analysis of disturbances in the frequency range between 2 kHz and 1 MHz. The spectrogram has proven a suitable tool for analyzing and visualizing these disturbances. Further knowledge is obtained on the disturbances arising from fluorescent lamps with high-frequency ballasts. Contrary to conventional knowledge, the main concern is in the so-called zero-crossing distortion. The level of this distortion component demonstrates a linear increase with the number of devices.

Ort, förlag, år, upplaga, sidor
Luleå: Luleå tekniska universitet, 2006. , s. 155
Serie
Licentiate thesis / Luleå University of Technology, ISSN 1402-1757 ; 2006:63
Nationell ämneskategori
Annan elektroteknik och elektronik Energiteknik
Forskningsämne
Elkraftteknik; Energiteknik
Identifikatorer
URN: urn:nbn:se:ltu:diva-26106Lokalt ID: cacc4230-a0aa-11db-8975-000ea68e967bOAI: oai:DiVA.org:ltu-26106DiVA, id: diva2:999265
Anmärkning
Godkänd; 2006; 20061206 (pafi)Tillgänglig från: 2016-09-30 Skapad: 2016-09-30 Senast uppdaterad: 2018-06-14Bibliografiskt granskad

Open Access i DiVA

fulltext(12659 kB)101 nedladdningar
Filinformation
Filnamn FULLTEXT01.pdfFilstorlek 12659 kBChecksumma SHA-512
172761cdcc2d96cb2aa352eb58e1e5dbd54ae2a55cf9b4cda0c95f5984d47c012ca6e033e1f7a356ba93c34b5f26dfcb70a9d989574578db3ae5159c9c40c3e8
Typ fulltextMimetyp application/pdf

Personposter BETA

Larsson, Anders

Sök vidare i DiVA

Av författaren/redaktören
Larsson, Anders
Av organisationen
Energivetenskap
Annan elektroteknik och elektronikEnergiteknik

Sök vidare utanför DiVA

GoogleGoogle Scholar
Totalt: 101 nedladdningar
Antalet nedladdningar är summan av nedladdningar för alla fulltexter. Det kan inkludera t.ex tidigare versioner som nu inte längre är tillgängliga.

urn-nbn

Altmetricpoäng

urn-nbn
Totalt: 136 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf