On high-frequency distortion in low-voltage power systems
Luleå tekniska universitet, Institutionen för teknikvetenskap och matematik, Energivetenskap.ORCID-id: 0000-0002-9103-0226
2011 (Engelska)Doktorsavhandling, sammanläggning (Övrigt vetenskapligt)
Abstract [en]

Power quality is a subject that has received a lot of attention during the last 10 to 20 years, both in industry and in academia. Power quality concerns interaction between the power grid and its customers and between the power grid and equipment connected to it, reflected in voltages and currents. Research and other developments in this area have to a great extent concentrated on relatively slow and low-frequency phenomena, with the main emphasis being on voltage dips (reductions in voltage magnitude with duration between about 50 ms and several seconds) and low-frequency harmonics (waveform distortion by frequency components up to about 2 kHz). These phenomena are reasonably well understood and several standards cover the area. For higher-frequency phenomena, above 2 kHz, there is no such general understanding, nor is there anything close to a complete set of standards covering this area. Modern energy efficient equipment connected to the grid, like fluorescent lamps but also solar panels, often uses switching technology, with switching frequencies that can range from a couple of kHz up to several hundreds of kHz. The grid is also used for communication of e.g. meter readings, system controls etc. This so-called power-line communication is using the same frequency range. The main frequency range of interest for this thesis has been the range from 2 to 150 kHz. There are two completely different measurement methods covering this frequency range: time-domain based and frequency-domain based. Time domain based measurements are used throughout the thesis. This gives an opportunity to choose between different analysing tools where among others the joint time-frequency domain has shown to be a useful tool for describing waveform distortion in our frequency range of interest. The majority of the measurements presented in this thesis have been directed towards fluorescent light powered by high frequency ballasts. This type of load has been, due to stringent harmonic limits, one of the first to use a more advanced switching technology called active power factor correction. This technique is also getting more frequently used in other small-power equipment, like computers. Installations of lights in stores etc. normally contain a large number of ballast connected together and the interaction is of importance, for example for setting emission and immunity standards. The measurements on ballasts presented in this work have shown that distortion in the frequency rage 2-150 kHz comes in three types: narrowband distortion; wideband distortion; and recurrent oscillations. The recurrent oscillations are a new type of powerquality disturbance that had not been recognized as such before. The measurements further have shown that the three types of distortion spread in a completely different way from the individual devices to the grid. This knowledge is essential for the setting of emission requirements on energy-efficient equipment.

Ort, förlag, år, upplaga, sidor
Luleå: Luleå tekniska universitet, 2011.
Serie
Doctoral thesis / Luleå University of Technology 1 jan 1997 → …, ISSN 1402-1544
Nationell ämneskategori
Annan elektroteknik och elektronik Energiteknik
Forskningsämne
Elkraftteknik; Energiteknik
Identifikatorer
URN: urn:nbn:se:ltu:diva-26658Lokalt ID: f614e609-6938-4bd0-a656-eece9cf3e2c2ISBN: 978-91-7439-218-0 (tryckt)OAI: oai:DiVA.org:ltu-26658DiVA, id: diva2:999825
Anmärkning
Godkänd; 2011; 20110216 (andlar); DISPUTATION Nedanstående person kommer att disputera för avläggande av teknologie doktorsexamen. Namn: Anders Larsson Ämnesområde: Energiteknik/Energy Engineering Avhandling: On High-Frequency Distortion in Low-Voltage Power Systems Opponent: Adj. professor Lars Gertmar, Institutionen för industriell elektroteknik och automation, Lunds universitet Ordförande: Professor Math Bollen, Institutionen för teknikvetenskap och matematik, Luleå tekniska universitet Tid: Onsdag den 23 mars 2011, kl 10.00 Plats: Hörsal A, Campus Skellefteå, Luleå tekniska universitetTillgänglig från: 2016-09-30 Skapad: 2016-09-30 Senast uppdaterad: 2018-06-14Bibliografiskt granskad

Open Access i DiVA

fulltext(14319 kB)322 nedladdningar
Filinformation
Filnamn FULLTEXT01.pdfFilstorlek 14319 kBChecksumma SHA-512
b7cbe1d659632b86e723fd39325a171b4acbddb50e061398c18ae2a88a8fa8908c5ca22306d835fff8dae3cf3d10e040b667a595a67179c8645bc64477d1a3ca
Typ fulltextMimetyp application/pdf

Personposter BETA

Larsson, Anders

Sök vidare i DiVA

Av författaren/redaktören
Larsson, Anders
Av organisationen
Energivetenskap
Annan elektroteknik och elektronikEnergiteknik

Sök vidare utanför DiVA

GoogleGoogle Scholar
Totalt: 322 nedladdningar
Antalet nedladdningar är summan av nedladdningar för alla fulltexter. Det kan inkludera t.ex tidigare versioner som nu inte längre är tillgängliga.

isbn
urn-nbn

Altmetricpoäng

isbn
urn-nbn
Totalt: 1785 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf