A study of the radiometric calibration of spectral bands in the mid-wave infrared (MWIR) spectral range 1.5-5 µm
Swedish Defence Research Agency.
Swedish Defence Research Agency.
Luleå University of Technology, Department of Engineering Sciences and Mathematics, Fluid and Experimental Mechanics.
2009 (English)In: Infrared Imaging Systems:: design, analysis, modeling, and testing XX : 14 - 16 April 2009, Orlando, Florida, United States / [ed] Gerald C. Holst, Bellingham, Wash: SPIE - International Society for Optical Engineering, 2009Conference paper, Published paper (Refereed)
Abstract [en]

Radiometric calibrations of sensor data are routinely performed using one or more radiation sources at different radiance levels. Calibration of spectral bands in the thermal infrared region (> 2.0 µm) is needed due to the bias drift which is a characteristic of the detector technology (e.g. MCT, InSb). To maintain the accuracy during an extended measurement the calibration has to be frequently repeated. The complexity of the radiometric calibration increases even more when a) the number of spectral bands to calibrate increases, b) the spectral range of the sensors to calibrate increases, c) the radiation level of the scene or object under interest (like hot spots) increases. If the accuracy in the calibration is to be maintained, all these factors will both increase the time needed to perform the calibration and the number and/or complexity of the radiation sources needed. Either or both may be impractical to handle during a field trial. In this paper we have studied the radiometric calibration of spectral bands in the mid wave infrared region (MWIR, 1.5 - 5.5 µm), with the focus on hot spots. The model and methodology proposed are however general and can be applied on an arbitrary set of sensor data collected in the 0.4 - 12 µm spectral region. Data was obtained from a cooled multi-band sensor based on an MCT detector. The study also includes the development of a SWIR source practical for field trials.

Place, publisher, year, edition, pages
Bellingham, Wash: SPIE - International Society for Optical Engineering, 2009.
Series
Proceedings of SPIE, the International Society for Optical Engineering, ISSN 0277-786X ; 7300
National Category
Applied Mechanics
Research subject
Experimental Mechanics
Identifiers
URN: urn:nbn:se:ltu:diva-30614DOI: 10.1117/12.818442Scopus ID: 69549086791Local ID: 479e84d0-1650-11df-bae5-000ea68e967bISBN: 978-0-8194-7566-4 (print)OAI: oai:DiVA.org:ltu-30614DiVA, id: diva2:1003843
Conference
Infrared Imaging Systems : Analysis, Modeling, and Testing 14/04/2009 - 14/04/2009
Note

Validerad; 2009; 20100210 (ysko)

Available from: 2016-09-30 Created: 2016-09-30 Last updated: 2018-02-27Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textScopus
By organisation
Fluid and Experimental Mechanics
Applied Mechanics

Search outside of DiVA

GoogleGoogle Scholar

doi
isbn
urn-nbn

Altmetric score

doi
isbn
urn-nbn
Total: 8 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf