In this paper, a low differential order model describing the dynamics of IMs with faulty stator is developed. The modelling is performed under well established idealizing assumptions regarding the magnetic and electrical properties of the motor. Typical motor faults as inter-turn short circuit and increased winding resistance are taken into account. The resulting model can be handled analytically and serve as a ground for fault detection and fault tolerant control of the IM. For each of the considered faults, very good agreement between simulations and experimental data collected from mass-produced industrial IMs is observed.
Godkänd; 2006; 20061228 (ysko)