Low-pressure gap discharge ultrasonic gas flowmeter
Luleå University of Technology, Department of Computer Science, Electrical and Space Engineering, Embedded Internet Systems Lab.ORCID iD: 0000-0002-4133-3317
2010 (English)In: The 15th International Flow Measurement Conference: FLOMEKO 2010 October 13-15 2010, Taipei Taiwan, 2010, p. 259-266Conference paper, Published paper (Refereed)
Abstract [en]

Low-pressure gas measurements are of increasing interest in the process industry for both control purposes and emission measurements. Industrial measurement environments include some very challenging components, such as:- Dust, particles, vapor, water droplets, etc.- Temperatures up to 1200°C- Pipe diameters of 1 to 10 mUltrasound flow measurement techniques have many advantages for such industrial measurement problems. Currently, a major problem is the lack of transducer technology that is sufficiently robust to operate in the presence of the above given industrial components. For the purpose of producing more robust technology, a gap discharge sound transmitter has been developed [1, 2]. Theoretical and experimental studies of the gap discharge transmitter indicate that flow measurement performances in the range of 1-2% of the actual flow is achievable [3]. Based on this gap discharge transmitter, an experimental ultrasound gas flowmeter was designed. The design features a gap discharge transmitter and piezo-based receivers. The design was tested in a real industrial environment. The test environment included heavy dust and water vapor in an exhaust pipe at a pelletization plant at LKAB, Kiruna, Sweden. The pipe diameter is 3 m, the pressure is ambient, and the gas flow speed is in the range of 5-20 m/s. The flow conditions were highly turbulent, using a straight pipe length ten times the pipe diameter in front of the experimental flowmeter. This paper presents the experimental gap discharge ultrasonic flowmeter design, the experimental setup and some measurement data. These data indicate that the gap discharge transmitter is feasible for operation in an industrial environment. Further preliminary flow measurement data demonstrate the feasibility of using a gap discharge transmitter as the sound-emitting source in an ultrasonic gas flowmeter.

Place, publisher, year, edition, pages
2010. p. 259-266
National Category
Other Electrical Engineering, Electronic Engineering, Information Engineering
Research subject
Industrial Electronics
Identifiers
URN: urn:nbn:se:ltu:diva-39052Scopus ID: 2-s2.0-84871589962Local ID: da434610-dc5f-11df-8b36-000ea68e967bOAI: oai:DiVA.org:ltu-39052DiVA, id: diva2:1012560
Conference
International Flow Measurement Conference : 13/10/2010 - 15/10/2010
Note
Godkänd; 2010; 20101020 (jerker)Available from: 2016-10-03 Created: 2016-10-03 Last updated: 2023-10-06Bibliographically approved

Open Access in DiVA

fulltext(1633 kB)370 downloads
File information
File name FULLTEXT01.pdfFile size 1633 kBChecksum SHA-512
8ae78c5f9d4367bda50008a913411f0a8950acf412ed24c748e7863adfc1d13fbbad3ad0cf8612f14f3ec03a8de5731d632c6524fb6517d2ce767085c50470d0
Type fulltextMimetype application/pdf

Scopus

Authority records

Delsing, JerkerKarlsson, Kristoffer

Search in DiVA

By author/editor
Delsing, JerkerKarlsson, Kristoffer
By organisation
Embedded Internet Systems Lab
Other Electrical Engineering, Electronic Engineering, Information Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 370 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 144 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf