Kartläggning av energieffektiviserings-åtgärder i nära nollenergi-flerbostadshus
2016 (Swedish)Independent thesis Advanced level (professional degree), 20 credits / 30 HE creditsStudent thesis
Abstract [en]

This thesis was conducted at Luleå University of Technology in cooperation with Norconsult AB and Lindbäcks Bygg AB during the autumn of 2015. The purpose of this work is to examine which energy saving measurements that are suitable for comprehending future demands in Swedish apartment buildings.Boverket has made a proposition to define near-zero energy (NZE) buildings, which will become the future standard for house construction. The allowed amount of energy used by buildings will decrease. The thesis have a depicted apartment building with district heating. It proves that only making changes to the building envelope is not enough to attain the threshold levels for NZE-buildings. Alternative energy systems are required that can recover lost heat and generate energy. The heat pump is a modern energy system used for heating the house, in new houses it will have to be replaced with alternative heating methods due to less profitable electricity heating.Different savings in energy measures for the building are made and are compared by the houses annual energy usage. Simulations prove that most energy are used to heating of ventilation, heating radiators and domestic hot water.Three systems have been evaluated in more detail. The systems were optimized and applied to the portrayed apartment building. 1. Heat recovery from ventilation.2. Heat recovery in the exhaust air duct placed after the heat recovery from ventilation. During summer it will be used to preheat domestic hot water.3. Solar collector for heating domestic hot water.Systems combined correspond to about 55% savings of all purchased electricity and heat needed to obtain a good indoor climate in the portrayed apartment building. These measures are sufficient to achieve the proposed energy requirements for NZE-buildings.

Place, publisher, year, edition, pages
2016. , 62 p.
Keyword [en]
Technology
Keyword [sv]
Teknik, Lågenergihus, fastighet, NNE, solpanel, FTX, BBR, återvinningsbatteri, ventilation, varmvatten, energisystem, hus, energibesparing, energiåtervinning
Identifiers
URN: urn:nbn:se:ltu:diva-43232Local ID: 11cb5f62-6ce4-4119-ab47-1e599e054266OAI: oai:DiVA.org:ltu-43232DiVA: diva2:1016461
Subject / course
Student thesis, at least 30 credits
Educational program
Sustainable Energy Engineering, master's level
Supervisors
Examiners
Note
Validerat; 20160329 (global_studentproject_submitter)Available from: 2016-10-04 Created: 2016-10-04Bibliographically approved

Open Access in DiVA

fulltext(2443 kB)104 downloads
File information
File name FULLTEXT02.pdfFile size 2443 kBChecksum SHA-512
1e4d547a586c86868ceb8aff5f2050d160b2c6af8b91c62c6382232a0ea6aedc5fd24bde8f728236be6e7a11662046d35b648fb0a4727532a715d7ed544ba4f6
Type fulltextMimetype application/pdf

Search in DiVA

By author/editor
Brahed, Joakim Thule

Search outside of DiVA

GoogleGoogle Scholar
Total: 104 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

Total: 406 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf