Säkerställning av driftsäkerhet och funktion för bröstvalsschaber på PM51
2012 (Swedish)Independent thesis Advanced level (professional degree), 20 credits / 30 HE creditsStudent thesis
Abstract [en]

The purpose with this master thesis is to investigate why the bolts in a doctor blade system breaks and to find a suitable action to prevent this. The doctor blade system can easily be explained as a scraper that cleans a roll. The scraper moves sideways (oscillates) and the doctor blade system along with the roll can be folded back for maintenance work.The work began with collecting relevant data about the doctor blade system. When this was done various sources of error that may have been causing the problems were listed and investigated more closely. Based on these studies, the cause of the failure has been concluded based on the most likely sources of error. The result shows three possible causes of accidents listed below:• A unit performing the oscillating movement that was mounted to the doctor blade system could have caused to high strain on the bolts• The movement that is created when the doctor blade system and the roll is folded back causes bending in the bearings• Too high load on the roll as a result of a wrongly adjusted doctor blade.Except these reasons, maintenance routines have been listed as a possible cause. This theory has higher insecurity and need to be investigated closer over a longer period of time.The problem with the oscillating unit is already resolved since it was replaced short before the work started. The folding movement has a unit installed that is meant to make the movement parallel, but this unit is malfunctioning. A suitable complement to this is a measurement system that ensures parallelism.The high load can be resolved by adjusting the doctor blade system to the roll.In addition to these proposed actions a suggestion for improvement has been made. This should be done by moving the adjustment for the doctor blade to a more beneficial position.

Place, publisher, year, edition, pages
2012.
Keywords [en]
Technology
Keywords [sv]
Teknik
Identifiers
URN: urn:nbn:se:ltu:diva-49798Local ID: 71c11e28-dc16-4bd2-9843-497ea0fac98eOAI: oai:DiVA.org:ltu-49798DiVA, id: diva2:1023146
Subject / course
Student thesis, at least 30 credits
Educational program
Mechanical Engineering, master's level
Supervisors
Examiners
Note
Validerat; 20120623 (anonymous)Available from: 2016-10-04 Created: 2016-10-04Bibliographically approved

Open Access in DiVA

fulltext(2181 kB)419 downloads
File information
File name FULLTEXT02.pdfFile size 2181 kBChecksum SHA-512
7e26efa14d188b9a522b39fcc339e3a6afbdf79ee42be24322d9860db4aa0534be47a5578219757f5cacce8403d5cb77ed08bb74410e24dc8da840e44061da0b
Type fulltextMimetype application/pdf

Search in DiVA

By author/editor
Isaksson, Martin

Search outside of DiVA

GoogleGoogle Scholar
Total: 419 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 51 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf