An empirical study of the spatial uncertainty of reverberation time measurement below 50 Hz
Luleå University of Technology, Department of Civil, Environmental and Natural Resources Engineering, Operation, Maintenance and Acoustics.ORCID iD: 0000-0002-8451-4804
Luleå University of Technology, Department of Civil, Environmental and Natural Resources Engineering, Operation, Maintenance and Acoustics.
Luleå University of Technology.
Number of Authors: 32016 (English)In: InterNoise 2016: 45th International Congress and Exposition on Noise Control Engineering: Towards a Quieter Future / [ed] von Estorff O., Kropp W., Schulte-Fortkamp B, German Acoustical Society , 2016, p. 3661-3665Conference paper, Published paper (Refereed)
Abstract [en]

The relevance of performing reverberation time measurements at very low frequencies became an issue in Sweden when the national standard recommended that impact sound insulation should be evaluated from 20 Hz for sound classes above the minimum requirement. Even though the standard states that L'n,T is not to be normalized with respect of reverberation time for frequencies below 50 Hz, it could be argued to include such a correction term to handle any possible variation in the absorption properties of the room. But this can be done only if the reverberation time can be accomplished with reasonable accuracy. The present paper presents an empirical study where reverberation time has been measured from 20 Hz in two different bedrooms with more than 100 microphone positions in each in order to determine the spatial variation. A comparison is made between the uncertainty as a function of frequency and it is indicated that the standard deviation is larger for the lowest frequencies, below 50 Hz, compared to higher. From an engineering point of view, this can be compensated by adding additional positions to the already existing ISO measurement procedure

Place, publisher, year, edition, pages
German Acoustical Society , 2016. p. 3661-3665
National Category
Fluid Mechanics and Acoustics
Research subject
Engineering Acoustics
Identifiers
URN: urn:nbn:se:ltu:diva-60713Scopus ID: 2-s2.0-84994633957OAI: oai:DiVA.org:ltu-60713DiVA, id: diva2:1050035
Conference
45th International Congress and Exposition on Noise Control Engineering,Hamburg, 21-24 August 2016
Available from: 2016-11-28 Created: 2016-11-28 Last updated: 2018-09-03Bibliographically approved

Open Access in DiVA

No full text in DiVA

Scopus

Authority records BETA

Ljunggren, FredrikÖqvist, Rikard

Search in DiVA

By author/editor
Ljunggren, FredrikÖqvist, RikardSimmons, Christian
By organisation
Operation, Maintenance and AcousticsLuleå University of Technology
Fluid Mechanics and Acoustics

Search outside of DiVA

GoogleGoogle Scholar

urn-nbn

Altmetric score

urn-nbn
Total: 249 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf