Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Downstream network modeling for switching transients in EHV networks containing cables
Eindhoven University of Technology.
LuleƄ University of Technology, Department of Engineering Sciences and Mathematics, Energy Science.ORCID iD: 0000-0003-4074-9529
TenneT TSO BV, Arnhem.
Eindhoven University of Technology.
Show others and affiliations
Number of Authors: 52017 (English)In: IEEE PES PowerTech Manchester 2017: towards and beyond sustainable energy systems, 2017, Piscataway, NJ: Institute of Electrical and Electronics Engineers (IEEE), 2017, article id 7980800Conference paper, Published paper (Refereed)
Abstract [en]

For the study of switching transients in Extra High Voltage (EHV) networks it is common practice to model a relatively small part of the EHV network. The downstream network is either disregarded or modeled as a parallel RC or RL circuit, based on the powerflow, directly at the secondary side of the transmission transformer. In this paper an investigation for the extent and model type of the downstream network (below 380 kV) is performed. A detailed model for an example downstream network is developed. Different simplifications and equivalent models are compared in frequency domain and in time domain, during cable energization. The impact of the lower voltage network on both the maximum overvoltage and the harmonic content during energization is assessed. Moreover, components that are of major importance are identified and proper equivalent models for the downstream network are proposed. Simulation results show that in particular the type of the 150 kV network (underground cable or overhead line) affects greatly both the maximum overvoltage and the harmonic content during energization. On the other hand, the parameters of end customer loads have only minor effect.

Place, publisher, year, edition, pages
Piscataway, NJ: Institute of Electrical and Electronics Engineers (IEEE), 2017. article id 7980800
National Category
Other Electrical Engineering, Electronic Engineering, Information Engineering
Research subject
Electric Power Engineering
Identifiers
URN: urn:nbn:se:ltu:diva-66244DOI: 10.1109/PTC.2017.7980800ISI: 000411142500014Scopus ID: 2-s2.0-85034777392ISBN: 978-1-5090-4237-1 (electronic)OAI: oai:DiVA.org:ltu-66244DiVA, id: diva2:1152341
Conference
12th IEEE PES PowerTech Conference, Manchester, June 18-22 2017
Available from: 2017-10-24 Created: 2017-10-24 Last updated: 2017-12-05Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textScopus

Authority records

Bollen, Math

Search in DiVA

By author/editor
Bollen, Math
By organisation
Energy Science
Other Electrical Engineering, Electronic Engineering, Information Engineering

Search outside of DiVA

GoogleGoogle Scholar

doi
isbn
urn-nbn

Altmetric score

doi
isbn
urn-nbn
Total: 283 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf