Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Numerical study of the Winter-Kennedy method: a sensitivity analysis
Luleå University of Technology, Department of Engineering Sciences and Mathematics, Fluid and Experimental Mechanics.ORCID iD: 0000-0001-5833-6736
Institut de recherche d'Hydro-Québec, Canada.
Norwegian University of Science and Technology, NTNU, Norway.
Luleå University of Technology, Department of Engineering Sciences and Mathematics, Fluid and Experimental Mechanics.ORCID iD: 0000-0001-7599-0895
2018 (English)In: Journal of Fluids Engineering - Trancactions of The ASME, ISSN 0098-2202, E-ISSN 1528-901X, Vol. 140, no 5, article id 051103Article in journal (Refereed) Published
Abstract [en]

The Winter-Kennedy (WK) method is commonly used in relative discharge measurement and to quantify efficiency step-up in hydropower refurbishment projects. The method utilizes the differential pressure between two taps located at a radial section of a spiral case, which is related to the discharge with the help of a coefficient and an exponent. Nearly a century old and widely used, the method has shown some discrepancies when the same coefficient is used after a plant upgrade. The reasons are often attributed to local flow changes. To study the change in flow behavior and its impact on the coefficient, a numerical model of a semi-spiral case (SC) has been developed and the numerical results are compared with experimental results. The simulations of the SC have been performed with different inlet boundary conditions. Comparison between an analytical formulation with the computational fluid dynamics (CFD) results shows that the flow inside an SC is highly three-dimensional (3D). The magnitude of the secondary flow is a function of the inlet boundary conditions. The secondary flow affects the vortex flow distribution and hence the coefficients. For the SC considered in this study, the most stable WK configurations are located toward the bottom from θ =30deg to 45deg after the curve of the SC begins, and on the top between two stay vanes.

Place, publisher, year, edition, pages
ASME Press, 2018. Vol. 140, no 5, article id 051103
Keywords [en]
Winter-Kennedy, Discharge, hydropower, Spiral-case
National Category
Fluid Mechanics and Acoustics
Research subject
Fluid Mechanics
Identifiers
URN: urn:nbn:se:ltu:diva-66441DOI: 10.1115/1.4038662ISI: 000427848100010Scopus ID: 2-s2.0-85044437186OAI: oai:DiVA.org:ltu-66441DiVA, id: diva2:1155307
Note

Validerad;2018;Nivå 2;2018-04-06 (svasva)

Available from: 2017-11-07 Created: 2017-11-07 Last updated: 2018-07-24Bibliographically approved
In thesis
1. A sensitivity analysis of the Winter-Kennedy method
Open this publication in new window or tab >>A sensitivity analysis of the Winter-Kennedy method
2018 (English)Licentiate thesis, comprehensive summary (Other academic)
Abstract [en]

Hydropower is among the lowest-cost electrical energy sources due to its long lifespan and lower operation and maintenance cost. The hydro-mechanical components of hydropower plants generally last about four to five decades, then they are either overhauled or replaced. The major upgrades and refurbishments of the hydropower plants that are ongoing have also been motivated by the introduction of new rules and regulations, safety or environmentally friendly and improved turbine designs. Whatever are the drivers, the refurbishments are usually expected to increase efficiency, flexibility and more power from the plant.

Efficiency measurement is usually performed after refurbishments. While it is relatively straightforward to measure efficiency in high head machines due to the availability of several code-accepted methods, similar measurements in low head plants remain a challenge. The main difficulty lies in the discharge/flow rate measurement. The reason is due to the continuously varying cross-section and short intake, as a result, the flow profile or parallel streamlines cannot be established. Among several relative methods, the Winter-Kennedy (WK) method is widely used to determine the step-up efficiency before and after refurbishment. The WK method is an index testing approach allowing to determine the on-cam relationship between blade and guide vane angles for Kaplan turbine as well. The method utilizes features of the flow physics in a curvilinear motion. A pair of pressure taps is placed at an inner and outer section of the spiral case (SC). The method relates discharge (Q) as Q=K(dP)^n, where K is usually called as the WK constant and n is the exponent whose value varies from 0.48 to 0.52. dP is the differential pressure from the pair of pressure taps placed on the SC.  

Although the method has very high repeatability, some discrepancies were noticed in previous studies. The reasons are often attributed to the change in local flow conditions due to the change in inflow conditions, corrosions, or change in geometry. Paper A is a review of the WK method, which includes the possible factors that can influence the WK method. Considering the possible factors, the aim of this thesis is to study the change in flow behavior and its impact on the coefficients. Therefore, a numerical model of a Kaplan turbine has been developed. The turbine model of Hölleforsen hydropower plant in Sweden was used in the study. The plant is considered as a low head with 27-m head and a discharge of 230 m3/s. The 1:11 scale model of the prototype is used as the numerical model in this study, which has 0.5 m runner diameter, 4.5 m head, 0.522 m3/s discharge and 595 rpm at its best efficiency point. A sensitivity analysis of the WK method has been performed with the help of CFD simulations. The numerical results are compared with the previously conducted experiment on the model. The study considers four different WK configurations at seven locations along the azimuthal direction. The simulations have been performed with different inlet boundary conditions (Paper B and Paper C) and different runner blade angles (Paper C). The CFD results show that the WK coefficients are sensitive to inlet conditions. The study also concludes that to limit the impact of a change in inflow conditions, runner blade angle on the coefficients, the more suitable WK locations are at the beginning of the SC with the inner pressure tap placed between stay vanes on the top wall.

Place, publisher, year, edition, pages
Luleå: Luleå University of Technology, 2018
Series
Licentiate thesis / Luleå University of Technology, ISSN 1402-1757
Keywords
Hydropower, discharge, Winter-Kennedy, CFD, Sensitivity
National Category
Fluid Mechanics and Acoustics Energy Engineering
Research subject
Fluid Mechanics
Identifiers
urn:nbn:se:ltu:diva-70157 (URN)978-91-7790-176-1 (ISBN)978-91-7790-177-8 (ISBN)
Presentation
2018-10-05, E246, Luleå, 13:00 (English)
Opponent
Supervisors
Available from: 2018-07-31 Created: 2018-07-24 Last updated: 2018-09-12Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textScopus

Authority records BETA

Baidar, Binaya

Search in DiVA

By author/editor
Baidar, BinayaCervantes, Michel
By organisation
Fluid and Experimental Mechanics
In the same journal
Journal of Fluids Engineering - Trancactions of The ASME
Fluid Mechanics and Acoustics

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 117 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf