Model based pulse shaping for detection of gamma rays
Luleå University of Technology, Department of Computer Science, Electrical and Space Engineering.
2017 (English)Independent thesis Advanced level (professional degree), 20 credits / 30 HE creditsStudent thesis
Abstract [en]

To analyse drill samples in a mine, a scanner that uses a gamma ray detector can be used. The scanner can analyse the drill sample to quickly see the elements present in the sample without destroying it. To improve the performance of the scanner, the electric signal from the detector needs to be less noisy, and different pulse shaping methods, filters and smoothers can be used on the sampled data to achieve an improved performance.

In this master thesis, the electric noise model of the electronics around the detector was modeled, and analysed. Different pulse shaping method, filters and smoothers was also tested to see which method gave the best performance in FWHM sense. The Full Width at Half Maximum (FWHM) is the energy resolution of a detector, and is defined as the full width of a photopeak at the half maximum. The noise model of the schematic for the preamplifier was made by hand with support from MATLAB. The resulting noise model was compared between MATLAB and LTspice, and the conclusion is that the JFET is the main contributor of the significant noise, contributing to 98 % of the total noise at 10 GHz.

The adopted filters and pulse shaping method are, matched filter, custom filter, CR-RC shaping, mean filter, median filter and clustering. The results from the tests indicated that custom filter with a FWHM of 1.96 keV and CR-RC with a FWHM of 1.67 keV shaping were more accurate than the matched filter with the FWHM of 5.1 keV. But the results also showed that it is important to take into account the waveform variance, due to inherent properties in the detector, with this consideration the FWHM of CR-RC shaper was improved from 2.29 keV to 1.67 keV. The clustering method was the most promising method but due to time constraints this method was never fully tested and no FWHM value was achieved.

Place, publisher, year, edition, pages
2017. , p. 72
Keywords [en]
pulse shaping, FWHM, CR-RC, electric noise model, analyse drill samples, gamma ray detector, matched filter, custom filter, clustering
National Category
Other Electrical Engineering, Electronic Engineering, Information Engineering Signal Processing
Identifiers
URN: urn:nbn:se:ltu:diva-66637OAI: oai:DiVA.org:ltu-66637DiVA, id: diva2:1158300
External cooperation
Conex AB
Educational program
Engineering Physics and Electrical Engineering, master's level
Supervisors
Examiners
Available from: 2017-11-28 Created: 2017-11-19 Last updated: 2017-11-28Bibliographically approved

Open Access in DiVA

No full text in DiVA

Search in DiVA

By author/editor
Ödmark, Fredrik
By organisation
Department of Computer Science, Electrical and Space Engineering
Other Electrical Engineering, Electronic Engineering, Information EngineeringSignal Processing

Search outside of DiVA

GoogleGoogle Scholar

urn-nbn

Altmetric score

urn-nbn
Total: 117 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf