Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Evaluating a constant-current load model through comparative transient stability case-studies of a synchronous-synchronous rotary frequency converter-fed railway
Luleå University of Technology, Department of Engineering Sciences and Mathematics, Energy Science.ORCID iD: 0000-0003-2109-060X
Luleå University of Technology, Department of Engineering Sciences and Mathematics, Energy Science.
Luleå University of Technology, Department of Engineering Sciences and Mathematics, Energy Science.ORCID iD: 0000-0003-4074-9529
2019 (English)In: 2019 Joint Rail Conference, ASME Press, 2019, article id V001T09A003Conference paper, Published paper (Other academic)
Abstract [en]

This paper continues the pursuit of getting a deeper understanding regarding the transient stability of low-frequency AC railway power systems operated at 16 2/3 Hz synchronously to the public grid. The focus is set on the impact of different load models. A simple constant-current load model is proposed and compared to a previously proposed and studied load model in which the train’s active power is regulated.

The study and comparison is made on exactly the same cases as and grid as with the already proposed and more advanced load model. The railway grid is equipped with a low-frequency AC high-voltage transmission line which is subjected to a fault. The study is limited to railways being fed by different distributions of RFC (Rotary Frequency Converter) types. Both AT (auto transformer) and BT (booster transformer) catenaries are considered.

The RFC dynamic models are essentially Anderson-Fouad models of two synchronous machines coupled mechanically by their rotors being connected to the same shaft.

The differences in load behaviour between the proposed constant-current load model and the previously proposed and studied voltage-dependent active power load model are analyzed and described in the paper.

Place, publisher, year, edition, pages
ASME Press, 2019. article id V001T09A003
National Category
Other Electrical Engineering, Electronic Engineering, Information Engineering
Research subject
Electric Power Engineering
Identifiers
URN: urn:nbn:se:ltu:diva-71801DOI: 10.1115/JRC2019-1249Scopus ID: 2-s2.0-85083953850OAI: oai:DiVA.org:ltu-71801DiVA, id: diva2:1266648
Conference
ASME/IEEE Joint Rail Conference, 9-12 April, 2019, Snowbird, Utah, USA
Note

ISBN för värdpublikation: 978-0-7918-5852-3

Available from: 2018-11-28 Created: 2018-11-28 Last updated: 2020-05-11Bibliographically approved
In thesis
1. Stability of Low-Frequency AC Railways: Models and Transient Stability
Open this publication in new window or tab >>Stability of Low-Frequency AC Railways: Models and Transient Stability
2019 (English)Doctoral thesis, comprehensive summary (Other academic)
Abstract [en]

Low-frequency AC railway grids are unique in the sense that a only few countries around the world uses them, still however, they are an important parts of their countries infrastructures. Due to the usage of a dierent frequency than the public grid of the country, conversion of frequency is needed for the interconnection. The frequency conversion is done by machine based rotary frequency converters or power electronic based static frequency converters.

When reinforcing with new power conversion capacity, mostly static frequency converters are installed since rotary frequency converters for railways have not been manufactured for some time. As more static frequency converterare introduced, the share of rotary frequency converters is reduced. It is not well explored how the stability of low-frequency AC railways is affected with a large share of static frequency converters.

In this thesis, the main goal has been to obtain knowledge of the stability of low-frequency AC railway grids, with focus on synchronous ones. The electromechanical stability of a synchronous low-frequency AC railway is explored through numerical simulations, where the transient stability is the main focus.

The main contributions of this thesis is proposing a model of a rotary frequency converter, proposing a model of a static frequency converter, and transient stability simulations. The model of the rotary frequency converter uses established machine models, whereas the static frequency converter model has been developed with help of measurements. It can be concluded that the proposed static frequency converter model captures the main behaviour of the measurements of a static frequency converter.

The transient stability of synchronous AC railway grids is studied, through numerical simulations. The studied cases are for instance dierent railway grid congurations with dierent types rotary frequency converters and railway grids with mixes of static frequency converters and static frequency converter.

The main conclusion is that the rotary frequency converter fed synchronous railway grids studied are transiently stable, and the studied railway grids where rotary frequency converters are gradually replaced with static frequency converter are also transiently stable. However, it was found that the studied railway grids obtain a heavier oscillatory behaviour when there is a mix of rotary frequency converters and static frequency converters.

Place, publisher, year, edition, pages
Luleå: Luleå University of Technology, 2019
Series
Doctoral thesis / Luleå University of Technology 1 jan 1997 → …, ISSN 1402-1544
National Category
Electrical Engineering, Electronic Engineering, Information Engineering Other Electrical Engineering, Electronic Engineering, Information Engineering
Research subject
Electric Power Engineering
Identifiers
urn:nbn:se:ltu:diva-71795 (URN)978-91-7790-292-8 (ISBN)978-91-7790-293-5 (ISBN)
Public defence
2019-02-28, Skellefteå, 10:00 (English)
Opponent
Supervisors
Available from: 2018-12-27 Created: 2018-12-13 Last updated: 2019-02-14Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textScopus

Authority records

Abrahamsson, LarsLaury, JohnBollen, Math

Search in DiVA

By author/editor
Abrahamsson, LarsLaury, JohnBollen, Math
By organisation
Energy Science
Other Electrical Engineering, Electronic Engineering, Information Engineering

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 426 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf